6
Operating instructions
Safety sensor
RSS36 AS
EN
7. Set-up and maintenance
7.1 Functional testing
The safety function of the safety components must be tested.
The following conditions must be previously checked and met:
1. Fitting of the sensor and the actuator.
2. Fitting and integrity of the power cable.
3. The system is free of dirt and soiling (in particular metal chips).
7.2 Maintenance
In the case of correct installation and adequate use, the safety switch-
gear features maintenance-free functionality.
A regular visual inspection and functional test, including the following
steps, is recommended:
1. Check the safety function
2. Check the fixing and integrity of the safety switchgear,
the actuator and the cable
3. Remove possible metal chips.
Measures must be taken to protect against manipulation or
against the bypassing of safety device, for example, using
an extra actuator
Damaged or defective components must be replaced.
8. Disassembly and disposal
8.1 Disassembly
The safety switchgear must be disassembled in a de-energised
condition only.
8.2 Disposal
The safety switchgear must be disposed of in an appropriate manner
in accordance with the national prescriptions and legislations.