3.  Mounting

3.1  General mounting instructions

 Fitting is only authorised in a de-energised condition

The enclosure can be fixed by means of 2 mounting holes.  The moun-
ting dimensions are mentioned at the rear of the enclosure.  The fixing 
screws must be protected against unauthorised tampering.  The use of 
a protective ground wire is imperative. The enclosure must not be used 
as an end stop. Any mounting position.

To ensure a proper functioning, the switch must be installed so that 
the required switch travel is obtained.  For safety functions, at least 
the positive break travel indicated in the switch travel diagram (refer to 
catalogue) must be obtained. All components have sufficient after-
travel to compensate for inaccuracies in the guidance of the actuating 
system.   The actuation of the switch beyond its end stop however must 
be avoided.

Please observe the recommendations regarding maximum 
impact energy, actuating speed and tightening torque in the 
technical data.

Please observe the remarks of the standards EN ISO 12100, 
EN 953 and EN ISO 14119.

3.2  Dimensions

All measurements in mm.

Position switches EX-Z/T 235

22

15

30

20

30

63,5

8,5

20

4,3

Mounting of the actuating heads

Repositioning the actuating heads (R, 1R, 4R, K, 3K, 4K, V.H)

The actuating head can be repositioned by 4 x 90°. Unscrew the four 
screws of the actuating head (Philips tip profile PZ1), reposition the 
actuating head in the desired position and retighten the four screws 
(tightening torque 0.45 Nm).

Repositioning the roller lever (H.)

The (offset) roller arm may be reversed, so that the roller faces the 
inside of the arm.

Positioning the lever (H.)

10° 10°

10°

10°

The roller lever can be repositioned over 360° on the toothed shaft in 
10° steps.  Unscrew the hexagonal screw approx. 4 mm, reposition the 
lever in the desired position and retighten the screw.

Length-adjustable lever (7H, 10H)

To adjust the length of the lever, unscrew the fixing screw of the lever. 
Firmly retighten the screw after the length adjustment.

Position switches with 7H, 10H actuator or spring rod lever 
AF are without positive break and not suitable for safety 
functions.
Ordering suffix for actuator 7H with positive break: -2138.

Summary of Contents for EX-Z/T 235

Page 1: ... below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention ru...

Page 2: ...inte nance requirements to the standard series EN 60079 must be met Conditions for safe operation Due to the specific impact energy the components must be fitted with a protection against mechanical stresses The specific ambient tempe rature range must be observed The user must provide for a protection against the permanent influence of UV rays The user must evaluate and design the safety chain in...

Page 3: ...n the technical data Please observe the remarks of the standards EN ISO 12100 EN 953 and EN ISO 14119 3 2 Dimensions All measurements in mm Position switches EX Z T 235 22 15 30 20 30 63 5 8 5 20 4 3 Mounting of the actuating heads Repositioning the actuating heads R 1R 4R K 3K 4K V H The actuating head can be repositioned by 4 x 90 Unscrew the four screws of the actuating head Philips tip profile...

Page 4: ...g to the instructions The connection is executed correctly The cable is correctly executed and connected Check the free movement of the actuating element The safety component is not damaged Remove particles of dust and soiling Check cable entry and connections in de energised condition 5 2 Maintenance In case of correct installation in accordance with the above described instructions the component...

Page 5: ...ective ATEX Afixing of the CE conformity mark 1 for safety components whose type plate is labelled safety component 2 for position switches without safety function Used harmonized standards EN 60947 5 1 EN 60079 31 EN 60079 0 EN 60079 15 Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal October 7 2014...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: