1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning to ensure the safe 
operation and disassembly of the safety switchgear. he operating 
instructions must be available in a legible condition and a complete 
version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards to 
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional informa-
tion.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machinery or plant.

The safety switchgear must be exclusively used in accordance with the 
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be 
found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet: www.
schmersal.net.

The information contained in this operating instructions manual is pro-
vided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded when safety switchgear is 
used. The relevant requirements of the standard ISO 14119 
must be observed.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 

Safety classiication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3
4.2  Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Appendix

7.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

x.000 / 03.2015 / v

.A.   -   101

193001-EN / D / 2015-03-12 / 

AE-Nr

. 4465

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 4

Translation of the original operating instructions

Summary of Contents for EX-TV.S 335

Page 1: ...the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further te...

Page 2: ...iecast paint finish Actuator stainless steel 1 4301 Max impact energy 4 J Actuating speed max 1 ms Protection class IP67 to EN 60529 Contact material Silver Contact type change over with double break Zb or 3 NC contacts galvanically separated contact bridges Switching system A IEC 60947 5 1 slow action NC contact with positive break Connection screw terminals Cable section min 0 75 mm max 2 5 mm i...

Page 3: ...ked and met The installation is executed according to the instructions The connection is executed correctly The cable is correctly executed and connected Check the free movement of the actuating element The safety component is not damaged Remove particles of dust and soiling Check cable entry and connections in de energised condition Check for correct installation of the hinge safety switch Check ...

Page 4: ...or the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal January 8 2015 Authorised signature Philip Schmersal Managing Dire...