2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

EX-TV

S 335-

Z-

-3D

No.

Option

Description

8

Shaft bore Ø 8 mm

10

Shaft bore Ø 10 mm

02

2 NC contacts

03

3 NC contacts

11

1 NO contacts / 1 NC contacts

12

1 NO contacts / 2 NC contacts

cable entry M20

Only if the information described in this operating instruc-
tions manual are realised correctly, the safety function and 
therefore the compliance with the Machinery Directive and 
the Explosion Protection Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The hinge safety switches are suitable for hinged guards in explosive at-
mospheres of Zone 22, category 3D, which need to be closed in order to 
provide for the necessary operational safety.  The installation and mainte-
nance requirements to the standard series EN 60079 must be met.

Conditions for safe operation

Due to the specific impact energy, the components must be fitted with a 
protection against mechanical stresses.  The specific ambient tempera-
ture range must be observed.

The user must evaluate and design the safety chain in ac-
cordance with the relevant standards and the required safety 
level.

2.4  Technical data

Equipment category: 

L

 II 3D

Ex protection:

 

Ex tc IIIC T90°C Dc X

Standards:

 

IEC 60947-5-1, EN 60079-0,  
EN 60079-31, BG-GS-ET-15

Enclosure:

 

light-alloy diecast, paint finish

Actuator:

 

stainless steel 1.4301

Max. impact energy:

 

4 J

Actuating speed:

 

max. 1 ms 

Protection class:

 

IP67 to EN 60529

Contact material:

 Silver

Contact type:

 

change-over with double break Zb,  

or 3 NC contacts, galvanically separated contact bridges

Switching system:

 

A

 IEC 60947-5-1; slow action, NC contact with 

positive break

Connection:

 

screw terminals

Cable section:

 

min. 0.75 mm² - max. 2.5 mm² 

(including conductor ferrules)

Cable entry:

 

M20 x 1.5

Rated impulse withstand voltage U

imp

:

 

6 kV

Rated insulation voltage U

i

:

 

500 V

Thermal test current I

the

:

 

10 A

Utilisation category:

 

AC-15 / DC-13

Rated operating current/voltage I

e

/U

e

:

 

4 A / 230 VAC  

4 A / 24 VDC

Max. fuse rating:

 

6 A gG D-fuse

Positive break travel:

 

10.7 mm

Positive break force:

 

each NC contact 5 N 

Ambient temperature:

 

 –20 °C … + 60 °C

Mechanical life:

 

max. 1 million operations

Switching frequency: 

max. 1000 / h

Shaft bore:

 

Ø 8 mm / 10 mm

Positive break angle:

 7°

Positive break torque:

 

0,6 Nm

Cable cross-section:

 

min. Ø 7 mm; max. Ø 12 mm

Cable glands:

 

L

 II 2GD

Tightening torque cover screws:

 

min. 1.0 Nm

Tightening torque cable gland:

 

min. 8 Nm

2.5  Safety classification

Standards: 

ISO 13849-1

B

10d

 (NC contact):

 20,000,000

Service life: 

20 years

MTTF

B

d

x

x

h

s/h

3600

d

10d

op

op

op

n

0,1 x n

op

t

cycle

(Specifications can vary depending on the application-specific parame-
ters h

op

, d

op

, t

cycle

 as well as the load.)

3.  Mounting

3.1  General mounting instructions

 Fitting is only authorised in a de-energised condition

The enclosure can be fixed by means of 4 mounting holes. The mount-
ing dimensions are mentioned at the rear of the enclosure.  The fixing 
screws must be protected against unauthorised tampering. The use of 
a protective ground wire is imperative. The enclosure must not be used 
as an end stop. Any mounting position.

Fit the hinge safety switch so that the shaft of the hinge safety switch 
is aligned with the pin of the door hinge.  Use the supplied tamperproof 
safety screws to fix the hinge safety switch.  To set the switching point, 
first adjust the plug/shaft connection by means of a threaded pin.  Then 
establish the positive link between the shaft and the door hinge.  To 
that effect, use the offset arranged mounting holes and the supplied 
spiral clamping pin.  The head can be turned by 4 x 90°.  Loosen the 
four screws of the head by means of a Torx screwdriver (T 20), turn the 
head in the desired position and retighten the screws.

Summary of Contents for EX-TV.S 335

Page 1: ...the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further te...

Page 2: ...iecast paint finish Actuator stainless steel 1 4301 Max impact energy 4 J Actuating speed max 1 ms Protection class IP67 to EN 60529 Contact material Silver Contact type change over with double break Zb or 3 NC contacts galvanically separated contact bridges Switching system A IEC 60947 5 1 slow action NC contact with positive break Connection screw terminals Cable section min 0 75 mm max 2 5 mm i...

Page 3: ...ked and met The installation is executed according to the instructions The connection is executed correctly The cable is correctly executed and connected Check the free movement of the actuating element The safety component is not damaged Remove particles of dust and soiling Check cable entry and connections in de energised condition Check for correct installation of the hinge safety switch Check ...

Page 4: ...or the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal January 8 2015 Authorised signature Philip Schmersal Managing Dire...

Reviews: