background image

EX-T. 454

Operating instructions

Belt alignment switches, position switches

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure  the 

safe operation and disassembly of the the product. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

It is the responsibility of the manufacturer of a machine or plant to 

ensure the correct functionality of the entire machine or plant.

The product must be exclusively used in accordance with the versions 

listed below or for the applications authorised by the manufacturer. 

Detailed information regarding the range of applications can be found in 

the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of 

the component, personal hazards or damage to machinery or 

plant components cannot be excluded. 

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .4

4.2  Switch travel diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

7  EU Declaration of conformity

x.000 / 04.2019 / v

.A. - 103025505-EN / 

A / 2019-04-10 / 

AE-Nr

. -

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Original

Summary of Contents for EX-T. 454 Series

Page 1: ...ons listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident preve...

Page 2: ...e borne in mind that the device may only be connected to a single approved and intrinsically safe apparatus e g SRB 200EXi barrier isolated switch amplifier Note external sources of heat and or cold The switch may only be operated in the temperature range specified in the datasheet External influences e g solar radiation external sources of cold must be borne in mind and precautionary measures tak...

Page 3: ...ous adjustment of lever position 360 LEV U14 B50 150 RVA 4 210 160 ø 50 ø14 For belt speeds of up to 6 m s Continuous adjustment of lever position 360 Roller lever A 1 0 0 14 12 20 60 36 5 7 8 9 Actuating speed max 3 m s min 0 05 m s with an actuating angle of α and β 30 Continuous adjustment of lever position 360 Splined shaft and lever available with 10 toothing Roller lever 2A 1 2 0 60 36 5 7 8...

Page 4: ...s must be fitted in accordance with the applicable operating instructions manual Cable glands are only authorised for permanent cables The constructor must provide for the necessary strain relief Ununused cable entries must be sealed by means of Ex approved locking screws Cable glands and locking screws are not included in the delivery After wiring the cover screws must be tightened uniformly Tigh...

Page 5: ...structions the component requires little maintenance For use in extreme conditions we recommend routine maintenance including the following steps 1 Check the free movement of the actuating element 2 Remove particles of dust and soiling 3 Check the correct fixing of the cover screws 4 Check for damages and correct fixing 5 Check cable entry and connections in a de energised condition Avoid electros...

Page 6: ... Stein 51105 Köln ID n 0035 Notified body TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 EU type examination certificate TÜV 17 ATEX 8004 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Phone 49 202 6474 0 Telefax 49 202 6474 100 E Mail info s...