3.  Mounting

3.1  General mounting instructions

• Fitting is only authorised in a de-energised condition.

• Do not use the sensor and the actuator as a mechanical backstop.

•  Any mounting position, provided that the active surfaces are opposite.

•  Inseparably fix the sensor and the actuator to the safety guard.

•  Do not install the safety sensor and the actuator in strong magnetic 

fields.

•  If possible, do not mount the sensor and the actuator on ferromagnetic 

material. When the sensor and the actuator are installed on 

ferromagnetic material, variations can be expected in the limit 

distances. The use of a non-magnetic spacer of at least  

5 mm thick must be used. The use of non-magnetic fixing screws is 

recommended also.

• Do not subject the safety sensor and actuator to extreme vibrations 

and shocks.

•  Keep away from metal chips.

•  The mounting distance between two sensors should always be at 

least 50 mm.

Also suitable for concealed mounting behind  

non-ferromagnetic covers.

3.2  Dimensions

All measurements in mm.

BNS 40 AS safety sensor

¤4.2

78

88

17.5

27

14.5

7

BNS 40S-…-C safety sensor

88

27

14.5

7

78

9.5

M4

BPS 40S- Actuator

¤4.2

78

88

9.5

27

14.5

BPS 40S-2 Actuator

¤4.2

78

88

17.5

27

14.5

BPS 40S-1-C Actuator

88

27

14.5

78

9.5

M4

BPS 40S-2-C Actuator

88

27

14.5

78

17.5

M4

3.3  Installation position and switch distance

0

2

4

6

8

5

7

5

6

5

5

4

4

2

2

BPS40S-1-C

0

2

4

6

8

5

7

5

6

5

5

4

4

2

2

BPS40S-2-C

3.4  Adjustment

Align the central markings of the safety sensor and the actuator  

with each other. The LED can only be used as rough setting tool. 

The correct functionality of both safety channels must be checked  

by means of the connected safety-monitoring module.

Recommended  Adjustment

Align the safety sensor and actuator at a distance of 0.5 x s