schmersal BNS 33S Series Operating Instructions Manual Download Page 2

8

Operating instructions
Safety sensor

BNS 33S

EN

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of the 
safety switchgear, personal hazards or damage to machin-
ery or plant components cannot be excluded. The relevant 
requirements of the standard EN 1088 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

BNS 33S-12Z

No.

Option

Description

without LED

G

with LED

BPS 33S Actuator

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The BNS 33S safety sensor is designed for application in safety circuits 
and is used for monitoring the position of movable safety guards to  
EN 1088 and IEC 60947-5-3. To actuate the safety sensors, only the 
BPS 33S actuators can be used.

The safety switches are used for applications, in which the hazardous 
situation is terminated without delay when the safety guard is opened.

Only the entire system consisting of the safety sensor (BNS 33S), the 
actuator (BPS 33S) and the safety-monitoring module (AES, SRB) 
meets the requirements of the standard IEC 60947-5-3.

Information for the selection of suitable safety-monitoring 
modules can be found in the Schmersal catalogues or in the 
online catalogue on the Internet: www.schmersal.net.

Technically, multiple safety sensors can be wired to one AES/SRB 
safety-monitoring module. To connect multiple safety sensors (check 
if authorised!), their NO contacts are wired in parallel and their NC 
contacts in series. The Protect-IE-11 or -02 or PROTECT-PE-11 (-AN) 
or -02 input expander module can be used to connect up to 4 safety 
sensors with NC/NC or NC/NO contacts.

In case of series-wiring at SRB max. 1 sensor with LED 
indication for U

N

.

Except for the Protect IE or Protect PE expander module, safety sen-
sors with LED must not be wired in series. The light intensity of the LED 
highly decreases due to the series-wiring and the voltage could drop 
below the minimum input voltage of the downstream safety-monitoring 
module. Please observe that the diagnostic coverage could decrease 
when multiple safety sensors are connected to one safety-monitoring 
module.

The user must evaluate and design the safety chain in ac-
cordance with the relevant standards and the required safety 
level.

If multiple safety components are wired in series, the Perfor-
mance Level to EN ISO 13849-1 will be reduced due to the 
restricted error detection under certain circumstances.

The entire concept of the control system, in which the safety 
component is integrated, must be validated to the relevant 
standards.

2.4  Technical data

Standards:

 

IEC 60947-5-3, BG-GS-ET-14

Enclosure:

 

V4A stainless steel to DIN 1.3960

Protection class:

 

IP69K (to IEC/EN 60529)

Termination:

 

connecting cable LiYY (food-safe) 

Connecting cable:

 

6 x 0.25 mm²

Operating principle:

 magnetic

Actuator:

 

BPS 33S, coded

Limit distances:

 

assured switching distance s

ao

:

 

8 mm

assured switch-off distance s

ar

:

 

18 mm

Switching condition indication:

 

LED only with ordering suffix G

Rated insulation voltage U

i

 

- without LED: 

125 VAC/DC

 

- with LED: 

32 VAC/DC

Rated impulse withstand voltage U

imp

 

-without LED: 

1.5 kV 

-with LED:

 

0.8 kV

Schaltspannung:

 

 

-without LED:

 

max. 100 VAC/DC 

-with LED:

 

max. 24 VDC

Switching current:

 

 

- without LED:

 

max. 250 mA 

- with LED:

 

max. 10 mA

Switching capacity:

 

 

-without LED:

 

max. 3 W 

-with LED:

 

max. 240 mW

Ambient temperature:

 

−25 °C ... +80 °C

Storage and transport temperature:

 

−25 °C ... +80 °C

Max. switching frequency:

 

5 Hz

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

10 ... 55 Hz, amplitude 1 mm

2.5  Safety classification

Standards:

 

EN ISO 13849-1

B

10d

 (NC/NO contact):

 25,000,000 

 

at max. 20 % contact load

Service life:

 

20 years

MTTF

B

d

x

x

h

s/h

3600

d

10d

op

op

op

n

0,1 x n

op

t

cycle

(Specifications can vary depending on the application-specific param-
eters h

op

, d

op

 and t

cycle

 as well as the load.)

An individual switch can be used in a category 3 or 4 architecture up to 
PL e.

mrl_bns33s_en.indd   8