The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed
1.6 Warning about misuse
In case of improper use or manipulation of the safety
switchgear, personal hazards or damages to machinery
or plant components cannot be excluded The relevant
requirements of the standard ISO 13850 must be observed
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions
and/or modifications to the device
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
BDF200-
➀
-
➁
-
➂
-
➃
-
➄
-
➅
-
➆
No. Option
Description
➀
SD
Variant for SD interface
FB
Variant for safety field box SFB
➁
Pos. 1
Command device
NH
Emergency stop without protective collar
NHK
Emergency stop with protective collar
➂
Pos. 2
Command and signalling device:
LT
Illuminated pushbutton
LM
Illuminated signal
DT
Pushbutton
PT
Mushroom push button
WS 2/ 3
Maintained selector switch, 2 or 3 positions
WT 2/ 3
Maintained spring-return rotary selector switch,
2 or 3 positions
SWS / SWT 20 Key-operated selector switch 2 positions
➃
Pos. 3
Command and signalling device:
LT
Illuminated pushbutton
LM
Illuminated signal
DT
Pushbutton
PT
Mushroom push button
WS 2/ 3
Maintained selector switch, 2 or 3 positions
WT 2/ 3
Maintained spring-return rotary selector switch,
2 or 3 positions
SWS / SWT 20 Key-operated selector switch 2 positions
➄
Pos. 4
Command and signalling device:
LT
Illuminated pushbutton
LM
Illuminated signal
DT
Pushbutton
PT
Mushroom push button
➅
without indicator lamp
G24
Indicator lamp G24, top
➆
2875
Pushbutton caps for pushbuttons and
illuminated pushbuttons
included in the kit
The unused positions 2 - 4 are labelled "B" and are sealed
with a blanking plug in factory
Only if the information described in this operating instructions
manual are realised correctly, the safety function and therefore
the compliance with the Machinery Directive is maintained
2.2 Special versions
For special versions, which are not listed in the order code below 21,
these specifications apply accordingly, provided that they correspond to
the standard version
2.3 Comprehensive quality insurance to 2006/42/EC
Schmersal is a certified company to appendix X of the Machinery
Directive As a result, Schmersal is entitled to autonomously conduct
the conformity assessment procedure for the products listed in
Appendix IV of the MD without involving a notified body The prototype
test certificates are available upon request or can be downloaded from
the Internet at wwwschmersalcom
2.4 Purpose
The modular BDF200-SD/FB control panel is installed on the safety
guard of a machine or plant It enables the operator to activate
functions such as, for instance, emergency stop, on/off and reset
The emergency stop command device is used on machinery and plants
as a safe command device to generate a safe signal initiating the
shutdown of a hazardous movement when actuated
The emergency stop command device may only be operated in
connection with a safety monitor
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level
The entire concept of the control system, in which the
safety component is integrated, must be validated to the
relevant standards
Maintenance:
Please observe that the safety function must
be triggered at least once a year to test the system!