Operating instructions

Control panel

BDF100

EN

After fitting, the cover screws must be tightened with a tightening torque 

of 0.7 … 0.8 Nm.

When closing the enclosure cover, ensure that the emergency 

stop module is fitted flush with the bottom section and that the 

cover screws are screwed in as far as they will go.

The emergency stop safety function must be checked by 

an appointed safety technician / safety representative once 

successfully installed.

3.4  Inscription plates

The marking on the inscription plates (included in delivery) is carried out 

by colour change by laser. The effects of heat may change the colour of 

the surface.

It must be ensured that the top is inscribed.

4.  Electrical connection

4.1  General information for electrical connection

The electrical connection may only be carried out by  

authorised personnel in a de-energised condition.

The connection to the operating panel is realised through an M12 

connector. The M12 connector plug is A-coded. The operating panel 

must be wired in accordance with the pin configuration of the connector 

plug.

4.2  Pin configuration

The number in brackets indicates the PIN number of the connector.

Control of the integrated or additional indicator lamp is through PIN 3 

and PIN 8.

BDF100-NH-…

1 NO contact / 2 NC contacts, contact variant emergency stop

5

8

4

3

2

1

7

6

13

21

14

(1)

(2)

(6)

(5)

(7)

(4)

22

X1

(8)

(3)

X2

12

11

BDF100-20-…

Contact variant -20, 2 NO contacts

0

1

2

13

23

14

24

13

14

(2)

(1)

(4)

(5)

23

(6)

(7)

24

X1

(8)

(3)

X2

5

8

4

3

2

1

7

6

BDF100-11-…

Contact variant -11, 1 NO contact / 1 NC contact

0

1

2

13

14

11

12

5

8

4

3

2

1

7

6

13

(6)

(1)

X1

(8)

14 (7)

(5)

11

(2)

(4)

12

(3)

X2

Information for selecting the suitable connectors and 

connector plugs can be found in the Schmersal catalogues or 

in the online catalogue on the Internet: www.schmersal.net.

5.  Set-up and maintenance

5.1  Functional testing

The function of the component must be tested. The following conditions 

must be previously checked and met:

1.  The installation is executed according to the instructions

2.  The connection is executed correctly

3.  The cable is correctly executed and connected.

5.2  Maintenance

In case of correct installation in accordance with the instructions 

described above, the component requires little maintenance. For use in 

extreme conditions, we recommend routine maintenance including the 

following steps:

1. Check the correct fixing of the control panel

2. Remove particles of dust and soiling

3. Check cable entry and connections

Damaged or defective components must be replaced.

6.  Disassembly and disposal

6.1  Disassembly

The product must be disassembled in a de-energised condition only.

6.2  Disposal

The product must be disposed of in an appropriate manner in 

accordance with the national prescriptions and legislations.

Summary of Contents for BDF100

Page 1: ... entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the cou...

Page 2: ...fety component Only if the information described in this operating instructions manual are realised correctly the safety function and therefore the compliance with the Machinery Directive is maintained 2 2 Actuator overview Emergency stop pushbutton without protective collar ordering suffix NH with protective collar ordering suffix NHK Pull to reset 1 NO contact 2 NC contact Illuminated pushbutton...

Page 3: ...ce to shock 100 g 6 ms Resistance to vibration 20 g 10 100 Hz Wiring configuration to IEC 60947 1 Actuating force at stroke end 1 NC 1 NO 8 N Lamp socket BA5S LED max length 17 mm LED change from front LED power consumption operating elements 16 mA Power consumption indicator lamp red 20 mA Adapters providing field wiring means are available from the manufacturer Refer to manufacturers information...

Page 4: ... contacts contact variant emergency stop 5 8 4 3 2 1 7 6 13 21 14 1 2 6 5 7 4 22 X1 8 3 X2 12 11 BDF100 20 Contact variant 20 2 NO contacts 0 1 2 13 23 14 24 13 14 2 1 4 5 23 6 7 24 X1 8 3 X2 5 8 4 3 2 1 7 6 BDF100 11 Contact variant 11 1 NO contact 1 NC contact 0 1 2 13 14 11 12 5 8 4 3 2 1 7 6 13 6 1 X1 8 14 7 5 11 2 4 12 3 X2 Information for selecting the suitable connectors and connector plugs...

Page 5: ...om We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component BDF100 Type See ordering code Description of the component Control panel Relevant Directives Machinery Directive 1 RoHS Directive 2006 42 EG 2011 65 EU Affixing of the CE conformity mark 1 for safety components whose type plate...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: