Operating instructions
Control panel
BDF100
EN
After fitting, the cover screws must be tightened with a tightening torque
of 0.7 … 0.8 Nm.
When closing the enclosure cover, ensure that the emergency
stop module is fitted flush with the bottom section and that the
cover screws are screwed in as far as they will go.
The emergency stop safety function must be checked by
an appointed safety technician / safety representative once
successfully installed.
3.4 Inscription plates
The marking on the inscription plates (included in delivery) is carried out
by colour change by laser. The effects of heat may change the colour of
the surface.
It must be ensured that the top is inscribed.
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
The connection to the operating panel is realised through an M12
connector. The M12 connector plug is A-coded. The operating panel
must be wired in accordance with the pin configuration of the connector
plug.
4.2 Pin configuration
The number in brackets indicates the PIN number of the connector.
Control of the integrated or additional indicator lamp is through PIN 3
and PIN 8.
BDF100-NH-…
1 NO contact / 2 NC contacts, contact variant emergency stop
5
8
4
3
2
1
7
6
13
21
14
(1)
(2)
(6)
(5)
(7)
(4)
22
X1
(8)
(3)
X2
12
11
BDF100-20-…
Contact variant -20, 2 NO contacts
0
1
2
13
23
14
24
13
14
(2)
(1)
(4)
(5)
23
(6)
(7)
24
X1
(8)
(3)
X2
5
8
4
3
2
1
7
6
BDF100-11-…
Contact variant -11, 1 NO contact / 1 NC contact
0
1
2
13
14
11
12
5
8
4
3
2
1
7
6
13
(6)
(1)
X1
(8)
14 (7)
(5)
11
(2)
(4)
12
(3)
X2
Information for selecting the suitable connectors and
connector plugs can be found in the Schmersal catalogues or
in the online catalogue on the Internet: www.schmersal.net.
5. Set-up and maintenance
5.1 Functional testing
The function of the component must be tested. The following conditions
must be previously checked and met:
1. The installation is executed according to the instructions
2. The connection is executed correctly
3. The cable is correctly executed and connected.
5.2 Maintenance
In case of correct installation in accordance with the instructions
described above, the component requires little maintenance. For use in
extreme conditions, we recommend routine maintenance including the
following steps:
1. Check the correct fixing of the control panel
2. Remove particles of dust and soiling
3. Check cable entry and connections
Damaged or defective components must be replaced.
6. Disassembly and disposal
6.1 Disassembly
The product must be disassembled in a de-energised condition only.
6.2 Disposal
The product must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.