1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed  

to execute safety-related functions as part of an entire plant or machine. 

It is the responsibility of the manufacturer of a machine or plant to 

ensure the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Actuator overview  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.5  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.6  Safety classification emergency stop. . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3  Fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.4  Inscription plates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .4

4.2  Pin configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7  EU Declaration of conformity

x.000 / 1

1.2018 / v

.A.   -   101214936-EN / E / 2018-10-25 / 

AE-Nr

.10081

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Original

Summary of Contents for BDF100

Page 1: ... entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the cou...

Page 2: ...fety component Only if the information described in this operating instructions manual are realised correctly the safety function and therefore the compliance with the Machinery Directive is maintained 2 2 Actuator overview Emergency stop pushbutton without protective collar ordering suffix NH with protective collar ordering suffix NHK Pull to reset 1 NO contact 2 NC contact Illuminated pushbutton...

Page 3: ...ce to shock 100 g 6 ms Resistance to vibration 20 g 10 100 Hz Wiring configuration to IEC 60947 1 Actuating force at stroke end 1 NC 1 NO 8 N Lamp socket BA5S LED max length 17 mm LED change from front LED power consumption operating elements 16 mA Power consumption indicator lamp red 20 mA Adapters providing field wiring means are available from the manufacturer Refer to manufacturers information...

Page 4: ... contacts contact variant emergency stop 5 8 4 3 2 1 7 6 13 21 14 1 2 6 5 7 4 22 X1 8 3 X2 12 11 BDF100 20 Contact variant 20 2 NO contacts 0 1 2 13 23 14 24 13 14 2 1 4 5 23 6 7 24 X1 8 3 X2 5 8 4 3 2 1 7 6 BDF100 11 Contact variant 11 1 NO contact 1 NC contact 0 1 2 13 14 11 12 5 8 4 3 2 1 7 6 13 6 1 X1 8 14 7 5 11 2 4 12 3 X2 Information for selecting the suitable connectors and connector plugs...

Page 5: ...om We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component BDF100 Type See ordering code Description of the component Control panel Relevant Directives Machinery Directive 1 RoHS Directive 2006 42 EG 2011 65 EU Affixing of the CE conformity mark 1 for safety components whose type plate...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...