Fault exclusion with regard to wiring routing must be
observed.
If for a certain application the quiescent current version of a
solenoid interlock cannot be used, for this exception an interlock
with power to lock can be used if additional safety measure
need to be realised that have an equivalent safety level.
3. Mounting
3.1 General mounting instructions
Four mounting holes are provided for fitting the solenoid interlock. The
solenoid interlock must not be used as an end stop. Any mounting
position. The mounting position however must be chosen so that the
ingress of dirt and soiling in the used opening is avoided. A smooth
insertion of the actuator in the enclosure must be ensured.
Mounting of the actuator
See actuator mounting instructions.
Please observe the relevant requirements of the standards
ISO 12100, ISO 14119 and ISO 14120.
The actuator must be permanently fitted to the safety guards
and protected against displacement by suitable measures
(tamperproof screws, gluing, drilling of the screw heads).