3
AZM 161 AS
Operating instructions
Solenoid interlock
EN
2.4 Technical data
Standards:
EN 50295, IEC 60947-5-1, EN ISO 13849-
1, IEC/EN 61508
Enclosure:
glass-ibre reinforced thermoplastic, self-
extinguishing
Actuator and locking bolt:
stainless steel 1.4301
Mechanical life:
> 1 million operations
Holding force F
max
:
2000 N
Latching force:
30 N, only for option R
Protection class:
IP 67 to IEC/EN 60529
Insulation protection class:
II,
X
Overvoltage category:
III
Degree of pollution:
3
Termination:
M12 x 1 connector, 4-pole
Electrical data
AS-Interface:
Operating voltage range:
26.5...31.6 VDC, through AS-Interface,
reverse polarity-proof
AS-interface power con-
sumption:
max. 0.25 A, ordering sufix "P" max.
0.1 A
Rated insulation voltage
U
i1
:
32 VDC
Rated impulse withstand
voltage U
imp1
:
800 V
Device fuse rating:
internally short-circuit proof
Speciication (V 2.1):
AS-i slave proile: S-7 .B.E,
IO-Code: 0x7,
ID-Code: 0xB,
ID-Code1: 0xF,
ID-Code2: 0xE
AS-interface inputs:
Databits D0...D3: condition static 0 or
dynamic code transmission SaW
AS-interface outputs:
Bit 0: magnet control solenoid interlock
Bit 1...bit 3: no function
Parameter port:
P0: actuator detected
P1: solenoid interlock locked
P2: magnet voltage in tolerance range
P3: error message "locking/unlocking of
the solenoid interlock blocked"
Diagnostic information:
LED yellow: channel 1 / AS-i SaW bit 0,1
LED green / red (AS-i duo LED): AS-
Interface supply voltage /
AS-Interface communication error or
slave address = 0 or periphery error
LED yellow: channel 2 / AS-i SaW bit 2,3
Input module address:
preset to address 0, can be changed
through AS-interface bus master or
hand-held programming device
Auxiliary voltage magnet:
only ordering sufix "P"
Operating voltage range:
24 VDC -15% / +10% (stabilised PELV)
Power consumption AUX:
max. 0.5 A
Rated insulation voltage
U
i2
:
32 VDC
Rated impulse withstand
voltage U
imp2
:
800 V
Device fuse rating:
≤ 4 A when used to UL 508
Magnet:
100% ED
Ambient conditions:
Ambient temperature:
-25 °C ... +60 °C
Storage and transport
temperature:
-25 °C ... +85 °C
Relative humidity:
30...95%, no condensation
Resistance to vibration:
10 ... 150 Hz, amplitude 0.35 mm
Resistance to shock:
30 g / 11 ms
Switching frequency f:
≤ 1 Hz
Switch-off delay:
< 100 ms
Actuating speed:
≤ 2 m/s
2.5
Safety classiication (approval under preparation)
Standards:
EN ISO 13849-1, IEC 61508
If a fault exclusion of a hazardous damage to the 1-channel me-
chanics is authorised and suficient protection against tampering is
ensured
PL:
up to d
Control category:
up to 3
PFH value:
1.01 x 10
-7
/ h
for ≤ 100,000 operations / year
SIL:
up to 2
Service life:
20 years
Basically suitable up to:
PL:
up to c
Control category:
up to 1
PFH value:
1.14 x 10
-6
/ h
for ≤ 100,000 operations / year
SIL:
up to 1
Service life:
20 years
3 Mounting
3.1 General mounting instructions
Three mounting holes are provided for ixing the enclosure. The sole
-
noid interlock is double insulated. The use of a protective ground wire
therefore is not authorised. The solenoid interlock must not be used
as an end stop. The solenoid interlock can be itted in any mounting
position. The mounting position however must be chosen so that the
ingression of dirt and soiling in the used opening is avoided. Unused
actuator openings must be sealed with slot sealing plugs.
Please observe the remarks of the standards EN ISO 12100,
EN 953 and EN 1088.
Mounting of the actuator
See mounting instructions actuators.
3.2 Dimensions
All measurements in mm.
90
56
M12
5,5
7
18
6
6
6
6
8
29
40
72
16,5
15,8
30
130
104
28
8
26
4 Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised
personnel in a de-energised condition.
The AZM 161 AS is supplied from the AS-Interface cable. The energy
for the locking magnets is either supplied separately (Aux) (ordering
sufix P) or through the AS-Interface cable. Both voltage supplies of the
solenoid interlock must be equipped with a protection against perma-
nent overvoltage. To that effect, stabilised PELV supply units must be
used.