1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
AZ 415-02/02YPK-2537-1
Only if the information described in this operating instructions
manual are realised correctly, the safety function and therefore
the compliance with the Machinery Directive is maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Purpose
Safety switches with separate actuators are suitable for movable safety
guards, which need to be closed to ensure the necessary operational
security.
The safety switches are used for applications, in which the hazardous
situation is terminated without delay when the safety guard is opened.
Operating principle
By closing the safety guard, switch insert S1 is released and switch insert
S2 actuated (differentiated operating principle). When the actuator is fully
inserted, the safety guard is not subject to any ejection force.
When the safety guard is opened, the NC contacts are positively
opened.
The safety switchgears are classified according to
ISO 14119 as type 2 interlocking devices.
The user must evaluate and design the safety chain in
accordance with the relevant standards and on the required
safety level.
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.
2.4 Technical data
Standards:
IEC 60947-5-1, BG-GS-ET-15
Enclosure:
light-alloy die-cast, enamel finish
Actuator:
zinc-plated metal / aluminium
Coding level according to ISO 14119:
low
Protection class:
IP65 to IEC 60529
Contact material:
gold flashed
Contact types:
2 NC contacts, with galvanically
separated contact bridges
Switching system:
A
IEC 60947-5-1
Connection:
screw terminals
Cable section:
0.75 … 1.5 mm
2
(incl. conductor ferrules)
Cable entry:
2 × M20 x 1.5
Rated impulse withstand voltage U
imp
:
4 kV
Rated insulation voltage U
i
:
250 V
Thermal test current I
the
:
6 A
Utilisation category:
AC-15
Rated operating current/voltage I
e
/U
e
:
4 A / 230 VAC
Max. fuse rating:
6 A gG D-fuse
Required short-circuit current:
1000 A
Positive break travel:
5 mm
Positive break force:
min. 15 N
(depending on the setting of the ball latch)
Ambient temperature
:
−25 °C … +70 °C
Mechanical life:
> 1 million operations
Latching force:
80 … 400 N (adjustable)
Actuating speed:
max. 0.2 m/s
Max. switching frequency:
2000/h
2.5 Safety classification
Standards:
ISO 13849-1
Envisaged structure:
- Basically:
applicable up to Cat. 1 / PL c
- With 2-channel usage and
fault exclusion mechanism*:
applicable up to Cat. 3 / PL d
with suitable logic unit
B
10D
NC contact:
2,000,000
Service life:
20 years
* If a fault exclusion to the 1-channel mechanics is authorised.
MTTF
B
d x
x
h
s/h
3600
D
10D
op
op
op
n
0,1 x n
op
t
cycle
(Determined values can vary depending on the application-specific
parameters h
op
, d
op
and t
cycle
as well as the load.)
If multiple safety components are wired in series, the Performance
Level to ISO 13849-1 will be reduced due to the restricted error
detection under certain circumstances.
3. Mounting
3.1 General mounting instructions
The mounting holes are accessible after removal of the cover.
The enclosure must not be used as an end stop. Any mounting position.
The mounting position however must be chosen so that the ingress of
dirt and soiling in the used opening is avoided.
Mounting of the actuators:
See mounting instructions actuators.
Please observe the remarks of the standards ISO 12100,
EN 953 and ISO 14119.
The safety component and the actuator must be
permanently fitted to the safety guards and protected
against displacement by suitable measures (tamperproof
screws, gluing, drilling, pinning).