background image

AZ/AZM 200-B40 

AZ/AZM 201-B40

Operating instructions

Actuator and Emergency exit

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure  the safe 

operation and disassembly of the the product. the operating instructions 

must be available in a legible condition and a complete version in the 

vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.5  Warning about misuse

In case of inadequate or improper use or manipulations of 

the component, personal hazards or damage to machinery 

or plant components cannot be excluded. The relevant 

requirements of the standard ISO 14119 must be observed.

1.6  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3.2  Representation of installation options  . . . . . . . . . . . . . . . . . . . . . . .2

3.3  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.4  Sequence of the steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Appendix

4.1  Set-up checklist  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

x.000 / 1

1.2017 / v

.A.   -   103016909-EN / 

A / 2017-1

1-10 / 

AE-Nr

. 8341

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for AZ 201-B40

Page 1: ...information can be found in the Schmersal catalogues or in the online catalogue on the Internet www schmersal net The information contained in this operating instructions manual is provided without liability and is subject to technical modifications There are no residual risks provided that the safety instructions as well as the instructions regarding mounting commissioning operation and maintenan...

Page 2: ... 3 Purpose In conjunction with the solenoid interlock or switch the actuator unit is suitable for hinged and sliding safety guards especially for hinged doors with overlapping folds The safety guard can be opened and closed from outside by turning the door handle The actuator is pulled into the actuator unit by a spring The actuator unit with emergency exit is used to open the safety guard inside ...

Page 3: ... 46 196 155 5 5 6 5 32 5 7 5 40 5 3 7 5 0 5 2 5 A B 115 115 65 18 5 78 37 220 6 5 155 5 73 165 36 5 5 6 5 32 5 7 5 40 7 5 0 5 2 5 94 68 50 25 172 5 max 170 K J1 Outside Inside AZ AZM 200 or AZ AZM201 with actuator unit G2 and emergency exit P1 94 68 50 25 172 5 max 170 K J2 Outside Inside Key A Manual release B Cable entry M20 x 1 5 J1 Actuator unit with door handle G1 J2 Actuator unit with door h...

Page 4: ...23 5 13 5 Ø10 29 12 5 85 Ø4 25 3 5 10 3 4 Sequence of the steps Step 1 To free mounting holes unscrew the cover C for the wiring compartment and open flap A for the manual release To be observed Actuation of manual release beneath flap with triangular key included in delivery A C GN RD YE Step 2 Enclosure of safety switchgear AZ AZM 200 and AZ AZM201 mounted flush with doorpost To be observed Scre...

Page 5: ...s DIN 125 6 4 included in delivery For applications with strong vibrations please observe a proper securing of the screws F Step 6 Mount the cover on the actuator unit To be observed Actuator unit completely retracted Step 7 Fit the door handle To be observed Fit the door handle P1 horizontal D for left hinged doors E for right hinged door Hexagonal screw A F 3 with screw lock included in delivery...

Page 6: ... with strong vibrations please observe a proper securing of the screws K J Step 12 Mounting emergency exit P1 Insert square rod H in the rear of the actuator unit To be observed Insert chamfer of the square into the emergency exit with either cut side of the square into the actuator unit Position of the chamfer as shown when actuator unit is actuated H Step 13 Mounting emergency exit P1 Fit the co...

Page 7: ... securing of the screws After the assembly of the emergency exit P20 proceed with step 17 For left hinged door For right hinged door Step 16 Mounting emergency exit P25 Fit emergency exit P25 to the door To be observed Insert square rod H in the actuator unit observe the direction of chamfer see step 12 Observe the position of the slotted hole Actuator completely inserted into the actuator unit J ...

Page 8: ...heck tight fitting of the dust proof flap 6 Functional testing The enabling signal is only transmitted to the safety circuit if the actuator is within range of the solenoid interlock and locked LED green yellow flashes yellow red STATUS Operating voltage Actuator inserted and locked for AZM 200 or AZM 201 Actuator inserted and not locked only for AZM 200 or AZM201 Error 7 Cover for manual release ...

Reviews: