4. Appendix
4.1 Set-up checklist
Operating instructions
Actuator and Emergency exit
AZ/AZM 200-B40
AZ/AZM 201-B40
1. Fixation:
All fixing screws installed and tightened with the specified torque
2. Distance:
Distance 7.5 +0.5/-2.5 mm between safety switchgear AZ/AZM 200 or AZ/AZM201
and actuator unit must be adhered to.
3. Emergency exit handle:
After locking, the correct closing of the door must be checked.
It should be possible to open the safety guard inside the hazardous area;
it should not be possible to lock the safety guard from inside
It should be possible to open the safety guard inside the hazardous area;
it should not be possible to lock the safety guard from inside. The emergency
exit handle must be in the upright position when closed.
4. Sticker emergency exit handle (included in delivery):
The sticker is visibly attached.
5. Dust shield cap:
Check tight fitting of the dust-proof flap
6. Functional testing:
The enabling signal is only transmitted to the safety circuit,
if the actuator is within range of the solenoid interlock and locked.
LED
green
yellow
flashes yellow
red
STATUS
Operating voltage
Actuator inserted (and locked for AZM 200 or AZM 201)
Actuator inserted and not locked (only for AZM 200 or AZM201)
Error
7. Cover for manual release:
Access cover or access hole is sealed (only for AZM 200 or AZM 201).
Date / Signature:
Checklist
Set-up and maintenance
Checking safety door handle system AZ/AZM 200 and AZ/AZM 201
Within the scope of commissioning and regular maintenance of the machine, the following items of
the safety door-handle system, consisting of AZM 200 or AZ/AZM 201, the corresponding actuator
unit and the emergency exit must be checked and inspected by a specialist: