schmersal AZ 200 T Operating Instructions Manual Download Page 6

6

Operating instructions
Safety switch

AZ 200 T

EN

8  Appendix

8.1  Wiring examples

The application examples shown are suggestions. They however do not 
release the user from carefully checking whether the switchgear and its 
set-up are suitable for the individual application.

Wiring example 1: AZ 200.-T-1P2P.

Y1

Y2

OUT

GND

24V

24V

X1

X2

IN

GND

24V

AZ 200.-T-1P2P

S12

A1

S22

A2

+24VDC

0V

SPS/PLC

OUT3

OUT1

OUT2

IN3

IN1

IN2

SRB

Wiring example 2: AZ 200.-T-3P2P.

S12

A1

S22

A2

+24VDC

0V

SPS/PLC

OUT3

OUT1

OUT2

GND

24V

OUT4

AZ 200.-T-3P2P

Y1

Y2

OUT

GND

24V

24V

OUT2

OUT3

IN

IN3

IN1

IN2

IN4

SRB

Wiring example 3: series-wiring of the AZ 200.-T-1P2P.

The series-wiring of multiple AZM 200 solenoid interlocks is realised by 
wiring in the control cabinet or in on-site junction boxes.

In the example, 3 AZ 200.-T-1P2P safety switches (max. 31 compo

-

nents) are wired in series.  The diagnostic output ("OUT") are separate

-

ly wired to a conventional PLC for evaluation or control. The maximum 
cable length of the safety circuits must not exceed 200 m.

In the series-wiring, the 24V-X1-X2 bridge must be removed from all 

components up to the last component (refer to wiring example).

AZ 200.-T-1P2P

Y1

Y2

OUT

GND

24V

24V

X1

X2

AZ 200.-T-1P2P

Y1

Y2

OUT

GND

24V

24V

X1

X2

AZ 200.-T-1P2P

Y1

Y2

OUT

GND

24V

24V

X1

X2

+24VDC

0V

IN

IN

IN

n participants 

max. 31 components 

in series

Diagnostic output

Safety outputs

Safety-monitoring module

8.2  Wiring
Table 4: wiring of the solenoid interlock with cable or with integra-
ted connector

Pin conigu

-

ration of the 
version with 
connector

Wiring, safety switch with 1 
diagnostic output ...-1P2P

Wiring, safety switch with 
serial diagnostic ...-SD2P

Wiring, safety switch with 3 
diagnostic outputs ...-3P2P

1

2

9

3

4

5

6

7

8

M12, 8-pole (sufix -ST2)

5

8

4

3

2

1

7

6

Pin 1

24 V Operating voltage

24 V Operating voltage

24 V Operating voltage

Pin 2

X1 Safety input 1

X1 Safety input 1

OUT 2 diagnostic output 2

Pin 3

GND Ground

GND Ground

GND Ground

Pin 4

Y1 Safety output 1

Y1 Safety output 1

Y1 Safety output 1

Pin 5

OUT diagnostic output

OUT SD output

OUT diagnostic output 1

Pin 6

X2 Safety input 2

X2 Safety input 2

OUT 3 diagnostic output 3

Pin 7

Y2 Safety output 2

Y2 Safety output 2

Y2 Safety output 2

Pin 8

IN (do not use)

IN SD input

IN (do not use)

Pin 9

spare

spare

spare

Sufix

-SK
-CC

AZ 200.-.-1P2P

Y1

Y2

OUT

GND

24V

24V

X1

X2

IN

AZ 200.-.-SD2P

Y1

Y2

OUT

GND

24V

24V

X1

X2

IN

AZ 200.-.-3P2P

Y1

Y2

OUT

GND

24V

24V

OUT2

OUT3

IN

Summary of Contents for AZ 200 T

Page 1: ...lated functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be...

Page 2: ...rror see lash codes yellow operating condition 2 4 Technical data Standards IEC 60947 5 3 EN ISO 13849 1 IEC 61508 Material of the enclosure glass ibre reinforced thermoplastic self extinguishing Mechanical life 1 million operations Latching force 30 N Protection class IP 67 to IEC EN 60529 Insulation protection class II X Overvoltage category III Degree of pollution 3 Realisation of the electrica...

Page 3: ...ly integrated in the safety circuit of the control system For applications up to PL e control category 4 to EN ISO 13849 1 the safety outputs of the safety switch max 31 components in a series wiring must be connected to a safety monitoring module of the same control category refer to wiring examp les Inductive loads e g contactors relays etc are to be provided with suitable interference suppressi...

Page 4: ...e following faults occur in that case the component can only be reset by switching off the operating voltage Cross wire short at the enabled safety outputs both safety outputs Y1 and Y2 bridged at Ub Error warning A fault has occured which causes the safety outputs to be disabled af ter 30 minutes The safety outputs initially remain enabled In this way the process can be shutdown in a controlled m...

Page 5: ...error warning is deleted when the error cause is eliminated Diagnostic error warning If an error warning is signalled in the response byte detailed fault information can be read out Flash codes red LED refer to table 2 Accessories for the series wiring To provide for a comfortable wiring and series wiring of SD compo nents the SD junction boxes SD 2V F SK variant for the ield in closed enclosure a...

Page 6: ...to the last component refer to wiring example AZ 200 T 1P2P Y1 Y2 OUT GND 24V 24V X1 X2 AZ 200 T 1P2P Y1 Y2 OUT GND 24V 24V X1 X2 AZ 200 T 1P2P Y1 Y2 OUT GND 24V 24V X1 X2 24VDC 0V IN IN IN n participants max 31 components in series Diagnostic output Safety outputs Safety monitoring module 8 2 Wiring Table 4 wiring of the solenoid interlock with cable or with integra ted connector Pin conigu ratio...

Page 7: ... basic design and const ruction conforms to the applicable European Directives Place and date of issue Wuppertal December 10 2009 Authorised signature Heinz Schmersal Managing Director Name of the safety component AZ 200 Description of the safety component Safety switch for safety functions Harmonised EC Directives 2006 42 EC EC Machinery Directive 2004 108 EC EMC Directive Person authorized for t...

Page 8: ... Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: