1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning for the safe operation 

and disassembly of the safety-monitoring module. the operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety-monitoring module must be exclusively used in accordance 

with the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

The entire concept of the control system, in which the 

safety component is integrated, must be validated to 

EN ISO 13849-2.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .3

5  Operating principle and settings

5.1  Operating principle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

8  Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

9  EU Declaration of conformity

x.000 / 1

1.2017 / v

.A.   -   101

126006-EN / H / 2017-1

1-17 / 

AE-Nr

. 8410

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Original

Summary of Contents for AES 1102

Page 1: ...e the correct functionality of the entire machine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in t...

Page 2: ...iding hinged and removable safety guards AES 1102 Monitoring one safety switch or multiple safety switches in series parallel circuits The number of connected safety switches is restricted by the contract transition resistance and the conduction resistance This overall resistance must not exceed 300 Ω For magnetic safety sensors with LED the brightness of the LED s reduce as the amount of guard do...

Page 3: ... do not automatically recognise the faults a regular check of the system is recommended The test intervals must be adjusted to the specific application hazard level mechanical and electrical stress If the safety guard is opened the enabling path of the safety monitoring module will open The machine is stopped Inputs AES 1102 C S14 S22 S32 Connect the safety switch with two NC contacts and one NO c...

Page 4: ...ety sensors U 24VDC YE GN GN GN YE YE PK GY GY GY PK PK BN WH WH WH BN BN e AES1102 L1 A1 K1 K3 A2 K2 S14 C 13 S22 S32 14 K4 3 N M AES 1112 Monitoring of two safety guards by means of a magnetic safety sensor AES1112 L1 A1 K1 K3 14 A2 K4 3 K2 S14 S14 C C Ue S22 S22 S1 S2 S32 S32 13 24VDC N M BK BK BU BU BN BN WH WH Key A Positive break A C S Non contact safety sensor ...

Page 5: ...es Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards DIN EN 60947 5 3 2014 DIN EN ISO 13849 1 2016 DIN EN ISO 13849 2 2013 Notified body for the prototype test DGUV Test Prüf und Zertifizierungsstelle Elektrotechnik Gustav Heinemann Ufer 130 50968 Köln ID n 0340 EC prototype test certificate ET 16118 Person authorised for the co...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: