2. Press the
or
button to select the desired function mode for the OUT1 output.
3. By pressing the
button, the next parameter is selected and the selected or set parameter
value is accepted.
6.3 Functions in the Main Menu
The following table shows an overview of the display codes and parameters in the main menu:
Parameter
Display code for
the lower dis-
play
Display code for
the main dis-
play
Explanation
OUT1 output
operating mode
ot1
oP5
One point set mode
XY5
Hysteresis mode
Window Comparator mode
OUT1 output
Switching logic
no
"normally open" NO mode
nC
"normally open" NC mode
OUT2 output
operating mode
This selection will not be dis-
played if only one output is avail-
able.
ot2
oFF
Output 2 deactivated
oP5
One point set mode
XY5
Hysteresis mode
Window Comparator mode
OUT2 output
Switching logic
This selection will not be dis-
played if only one output is avail-
able or if output 2 is deactivated
(
off
).
no
"normally open" NO mode
nC
"normally open" NC mode
Response time
rE5
2.5
25
100
2.5 ms
25 ms
100 ms
250 ms
14 / 40
EN-US · 30.30.01.02016 · 01 · 11/19