Setting of switching points for the signal output with [H-2] and [h-2]
The activation value
[H-2]
(when configuring the
[no]
output) and hysteresis
[h-2]
of the
parts control signal output are set using this function.
When the
[H-2]
value is reached or exceeded, then the H2 LED is also switched on.
The switching points of the parts control signal output are set as follows:
Press the
button.
Enter a valid PIN if the menu is locked.
Select the desired
[H-2]
or
[h-2]
parameter using the
or
buttons.
Confirm by pressing the
button.
Change the value using the
or
buttons.
Press the
button to save the changed value.
The display automatically jumps to the next setting value.
When the
or
button is pressed for approx. 3 seconds, the value to be
changed is scrolled through quickly.
The value is not accepted when exited using the
button.
Changes to the configuration of the
[no]
or
[nc]
signal output are made in the
configuration menu.