Schmalz SCGS Assembly Instructions Manual Download Page 8

9  Spare and Wearing Parts

Maintenance work may only be carried out by qualified personnel.

The following list contains the primary spare parts.

Type

Designation

Part no.

FLSA 20 NBR-AS-55

Flat suction gripper (round)

10.01.06.03934

FLSA 30 NBR-AS-55

Flat suction gripper (round)

10.01.06.03935

FLSA 20 NBR-ESD-55

Flat suction gripper (round)

10.01.06.04220

FLSA 30 NBR-ESD-55

Flat suction gripper (round)

10.01.06.04214

FLSA 40 NBR-ESD-55

Flat suction gripper (round)

10.01.06.04390

FLSA 50 NBR-ESD-55

Flat suction gripper (round)

10.01.06.04388

FLSA 20 SI-HD

Flat suction gripper (round)

10.01.06.03888

FLSA 30 SI-HD

Flat suction gripper (round)

10.01.06.03746

FLSA 40 SI-HD

Flat suction gripper (round)

10.01.06.03886

FLSA 50 SI-HD

Flat suction gripper (round)

10.01.06.03467

SAUG-FL SCGS 30 POM

Suction area POM Ø 30 mm

10.01.30.00894

10  Accessories

The following list contains the primary accessories.

Type

Designation

Part no.

SAUG-FL SCGS 30 POM

Suction area

10.01.30.00894

SAUG-SCGS 20 NBR-AS-55

Flat suction cup (round)

10.01.30.00898

SAUG-SCGS 30 NBR-AS-55

Flat suction cup (round)

10.01.30.00899

SAUG-SCGS 20 NBR-ESD-55

Flat suction cup (round)

10.01.30.00802

SAUG-SCGS 30 NBR-ESD-55

Flat suction cup (round)

10.01.30.00876

SAUG-SCGS 40 NBR-ESD-55

Flat suction cup (round)

10.01.30.00914

SAUG-SCGS 50 NBR-ESD-55

Flat suction cup (round)

10.01.30.00915

SAUG-SCGS 20 SI-HD

Flat suction cup (round)

10.01.30.00916

SAUG-SCGS 30 SI-HD

Flat suction cup (round)

10.01.30.00917

SAUG-SCGS 40 SI-HD

Flat suction cup (round)

10.01.30.00918

SAUG-SCGS 50 SI-HD

Flat suction cup (round)

10.01.30.00919

STV-W G1/8-AG 6 

1)

Plug-in screw union with swiveling angular design

10.08.02.00288

STV-W M5-AG 6 

2)

Plug-in screw union with swiveling angular design

10.08.02.00296

VSL 26-19 PVC-G

Vacuum hose

10.07.09.00007

1)

 Suitable for “suction” compressed air connection

2)

 Suitable for “blow-off” compressed air connection

11  Warranty

This system is guaranteed in accordance with our general terms of trade and delivery. The same applies to spare
parts, provided that these are original parts supplied by us.

Wearing parts are not covered by the warranty.

12  Disposing of the product

4

Sort and dispose of all components according to the country-specific regulations.

For proper disposal, please contact a company specializing in the disposal of technical goods and in-
struct the company to observe the applicable disposal and environmental regulations. Schmalz is happy
to assist you in finding a suitable company.

8 / 8

EN-US · 30.30.01.01918 · 00 · 02/19

Summary of Contents for SCGS

Page 1: ...z GmbH 02 19 This document is protected by copyright J Schmalz GmbH retains the rights established thereby Reproduction of the contents in full or in part is only permitted within the limits of the legal provisions of copyright law Any mod ifications to or abridgments of the document are prohibited without explicit written agreement from J Schmalz GmbH J Schmalz GmbH Johannes Schmalz Str 1 72293 G...

Page 2: ... heed these instructions If you still have questions after reading the technical documentation contactSchmalz service at www schmalz com services 1 3 Warnings in This Document Warnings warn against hazards that may occur when handling the product This document contains warnings re garding two levels of danger which you can recognize by the signal words Signal word Meaning WARNING Indicates a mediu...

Page 3: ...spheres Use in medical applications Lifting people or animals Evacuation of objects that are in danger of imploding 2 5 Modifications to the Product Schmalz assumes no liability for consequences of modifications over which it has no control 1 The product must be operated only in its original condition as delivered 2 Use only original spare parts from Schmalz 3 The product must be operated only in ...

Page 4: ...ature range C 5 75 Recommended internal hose Ø for suction mm 4 Recommended internal hose Ø for blow off mm 4 Recommended hose diameter for exhaust air mm 26 19 Mass g 95 Operating medium Use only well maintained compressed air air or neutral gas according to EN 983 filtered to 40 µm oiled or unoiled Feature Unit Operating pressure 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 Air consumption 1 l min 60 77 ...

Page 5: ...missing 2 Damage caused by defective packaging or in transit must be reported immediately to the carrier and J Schmalz GmbH 6 Installation 6 1 Installation Instructions CAUTION Compressed air or vacuum in direct contact with the eye Severe eye injury 4 Wear eye protection 4 Do not look into compressed air openings 4 Do not look into vacuum openings e g suction cups CAUTION Noise pollution due to i...

Page 6: ...r These must be observed 6 2 Mechanical Attachment Use only the connections mounting holes and attachment materials that have been provided The flow gripper may be installed in any position The flow gripper SCGS can be adapted to your handling system using the thread integrated in the holder 1 Use the G4 female thread of size G to mechani cally fasten the SCGS 2 Use the G1 male thread of size M20x...

Page 7: ...to be handled can then be gripped and transported The blow off compressed air connection 12 can be activated to deposit the object quickly No compressed air may be present at the suction connection 1 for this to occur 8 Cleaning the Flow Gripper 1 For cleaning do not use aggressive cleaning agents such as industrial alcohol white spirit or thinners Only use cleaning agents with pH 7 12 2 Remove di...

Page 8: ... SAUG SCGS 30 NBR ESD 55 Flat suction cup round 10 01 30 00876 SAUG SCGS 40 NBR ESD 55 Flat suction cup round 10 01 30 00914 SAUG SCGS 50 NBR ESD 55 Flat suction cup round 10 01 30 00915 SAUG SCGS 20 SI HD Flat suction cup round 10 01 30 00916 SAUG SCGS 30 SI HD Flat suction cup round 10 01 30 00917 SAUG SCGS 40 SI HD Flat suction cup round 10 01 30 00918 SAUG SCGS 50 SI HD Flat suction cup round ...

Reviews: