Start

up

 

 

Before

 

initial

 

start

up,

 

the

 

pump

 

must

 

be

 

filled

 

with

 

liquid

 

one

 

time

 

so

 

that

 

the

 

suction

 

stage

 

can

 

create

 

a

 

vacuum.

 

During

 

subsequent

 

shutdown,

 

enough

 

residual

 

liquid

 

always

 

remains

 

in

 

the

 

pump

 

so

 

that

 

a

 

restart

 

can

 

take

 

place

 

without

 

refilling.

 

 

 

The

 

centrifugal

 

pump

 

is

 

sealed

 

with

 

a

 

mechanical

 

seal

 

on

 

the

 

shaft.

 

This

 

dynamic

 

seal

 

may

 

not

 

run

 

dry

 

and

 

must

 

always

 

be

 

lubricated

 

with

 

liquid.

 

This

 

seal

 

was

 

placed

 

after

 

the

 

centrifugal

 

pump

 

stages

 

and

 

after

 

the

 

suction

 

stage.

 

For

 

this

 

arrangement,

 

the

 

seal

 

is

 

always

 

protected

 

against

 

a

 

dry

 

run

 

even

 

during

 

priming

 

when

 

there

 

is

 

very

 

little

 

liquid

 

in

 

the

 

pump.

 

 

The

 

suction

 

line

 

(max.

 

3m)

 

should

 

be

 

as

 

short

 

as

 

possible

 

and

 

guided

 

vertically

 

(always

 

rising!)

 

out

 

of

 

the

 

suction

 

tank.

 

This

 

is

 

decisive

 

for

 

a

 

good

 

suction

 

function

 

of

 

the

 

pump.

 

Suction

 

lifts

 

up

 

to

 

max.

 

2m

 

are

 

possible.

  

 

When

 

priming,

 

air

 

is

 

first

 

drawn

 

into

 

the

 

inside

 

of

 

the

 

pump.

 

A

 

ventilation

 

option

 

must

 

be

 

provided.

 

The

 

pressure

 

line

 

must

 

be

 

open

 

(without

 

non

return

 

valve)

 

or

 

a

 

small

 

ventilation

 

line

 

should

 

be

 

installed.

 

 

 

 

KSP03

 

3208

  ‐  

2

 

Liters

KSP06

 

3208

  ‐  

2.5

 

Liters

 

KSP09

 

3208

  ‐  

3

 

Liters

Summary of Contents for KSP 3208 Series

Page 1: ...pump consists of two pump types that are mounted on a drive shaft A multi stage centrifugal pump can then only operate when the inside of the pump is always filled with liquid This works very well when the pump has an inflow or the suction line is always completely filled For example this is possible by using a foot valve If the pump has a suction lift instead of an inflow and no foot valve can be...

Page 2: ...id This seal was placed after the centrifugal pump stages and after the suction stage For this arrangement the seal is always protected against a dry run even during priming when there is very little liquid in the pump The suction line max 3m should be as short as possible and guided vertically always rising out of the suction tank This is decisive for a good suction function of the pump Suction l...

Page 3: ...lift or suction losses too high Shorten suction line always install rising Maximum suction lift of 2m possible Suction line leaky Check suction line Pressure line is closed ventilation option missing Open pressure line without non return valve or install ventilation bypass Wrong direction of rotation Check direction of rotation observe arrow for incorrect direction of rotation swap the two phases ...

Page 4: ...hat can only be completely replaced if required Please observe the spare parts drawing After removing the suction stage Pos 111 proceed further as described in BA 27224 Reassembly Assembly is essentially disassembly in the reverse order Check all parts for wear Damaged parts must always be replaced by new ones Mechanical seals and all other seals are not wear free and should be checked for damage ...

Page 5: ...27249 Supplementary Operating Manual for Type KSP 3208 Supplementary OM Type KSP 5 Version 27249 v02 Spare parts drawing ...

Page 6: ...sher to 433 554 Distance washer to 922 554 02 Distance washer to 905 802 Block motor 819 Motor shaft 903 Plug screw 904 Threaded pin to 506 905 Connecting screw 920 Hexagonal nut to 905 922 Impeller cap nut 932 02 Retaining ring to 433 940 Key to 109 147 940 02 Key to 111 Not all parts are installed in every pump Suction stage Pos 111 is an assembly that can only be completely replaced if required...

Reviews: