background image

Quick Start Guide | Uni-M Panduit Ferrule Applicator in UniCrimp 200

 

Edition 1.4P (09-2019) 

www.schleuniger-na.com

 

2

3

 

 

Programming split cycle and press timing 

Step 

Change

 

Screen 

Value 

Starting from the “Counters: / Batch:” screen, press the 
following buttons in the sequence described.    

 

Counters: / Batch: 

 

Enter 

Screen changes to

 

Menu: Counters 

 

Screen changes to

 

Menu: Functions 

 

Enter 

Screen changes to

 

Crimp Speed 

100% 

Screen changes to

 

Crimp Force 

Off 

Screen changes to

 

Pneum Valve 

Off 

Screen changes to

 

Split Cycle 

Off 

Enter 

Enter highlights “Off”

 

Split Cycle  

Off 

+ changes “Off” to “On”

 

Split Cycle  

On 

Enter 

Enter confirms change and highlights 
the value

 

Split Cycle  

80

º

 

(press and hold to get a value of 160º)

 

Increments value

 

Split Cycle  

160

º

 

Enter 

Enter confirms change

 

Split Cycle  

 

(if necessary, use the +/- keys to change value)

 

Screen changes to

 

Split Cycle Speed 

5% 

[Esc]  

Screen changes to

 

Menu: Functions 

 

[Esc] 

Screen changes to

 

Counters: / Batch: 

 

Verify/set crimp height dials 

1.

 

Ensure the top crimp height dial (10) is set properly according to the Index value on the ID plate.

 

 

2.

 

Each major increment represents an index value of the number divided by 10 

a.

 

Examples:  

Dial setting on 8 refers to an index setting of 0.8. 

b.

 

Example:  

Dial setting on 19 refers to an index setting of 1.9.

 

 

c.

 

Photo shown of the dial refers to an index setting of approximately 1.94. 

3.

 

Each increment (or click) of the top dial changes the crimp height by in a 0.01mm. This is also used for the 
index value. 

a.

 

To achieve an index setting of 0.85, start at “8” on the top crimp dial (9) and turn the dial clockwise 5 clicks (0.80 + 
5*0.01 = 0.85) 

b.

 

To achieve an index setting of 1.23, start at “12” on the top crimp dial (9) and turn the dial clockwise 3 clicks (1.20 + 3*0.01 = 1.23) 

Load the ferrules  

11.

 

Remove air pressure to the applicator.  

12.

 

Bring the press ram to the top center position using the jog buttons.  

13.

 

Lift the safety shield.

 

 

14.

 

Remove the funnel unit (11). 

15.

 

Lift the ferrule brake lever (12). 

16.

 

Select the proper ferrule according to the applicator ID plate. 

17.

 

Install ferrule strip until the first ferrule reaches the end of the track. 

18.

 

Lower the ferrule brake lever (12). 

19.

 

Apply air pressure to the applicator and lower the safety shield. 

20.

 

Lower the tooling with the jog button.                  If the ferrule strip is advanced properly, the tooling will capture the first ferrule properly.  

13 

12 

11 