Quick Start Guide | Uni-M Panduit Ferrule Applicator in UniCrimp 200
Edition 1.4P (09-2019)
www.schleuniger-na.com
1
3
This document is intended to assist users of the Uni-M ferrule applicator on setup and minor adjustments when used with
Panduit strip form ferrules
. The
press used in this example is the UniCrimp 200 with pneumatic kit. Other presses should provide comparable results; however, split cycle function is
required on the press.
Applicators
Applicator
Wire Size
Inserter Kit
Funnel I.D.
Crimp Height
Index
Uni-M 1516
20AWG / 0.50mm
2
K008701
2.4mm / 0.09”
0.83mm / 0.033”
2.0
18 AWG / 0.75mm
2
K008175
2.8mm / 0.11”
0.94 – 1.04mm / 0.037 - 0.041”
2.1
18AWG / 1.0mm
2
K006667
3.3mm / 0.13”
0.99 – 1.02mm / 0.039 - 0.040”
2.1
16 AWG / 1.5mm
2
1.25 – 1.27mm / 0.049 - 0.050”
1.7
14 AWG / 2.5mm
2
K008585
3.6mm / 0.14”
1.55 – 1.80mm / 0.061 - 0.071
1.6
Installing the applicator into the press
Mounting
1.
Release the base plate clamping lever (1) by lowering it completely until it comes to a stop.
2.
Place the upper ram bolt (2) of the applicator into the press ram coupling (3) and lower the
applicator until the base rests on the bottom base plate (4). Be sure that the upper ram bolt (2)
remains in the ram coupling (3).
3.
Lift the clamping lever (1) to lock the applicator into position. Firmly grasp the applicator and try to
move it to ensure it is secure.
4.
Remove the red tooling protection ring (5) if it is still installed.
NOTE:
Be sure to install the protection ring whenever the applicator is
not in use. This part is very important to prevent damage to the tooling
when the applicator is not in use.
Air connection
5.
The “Pneum Valve” setting in the interface “Functions” menu should be set to “Off”. Although the applicator requires air, the feed timing is
handled internally in the applicator. Therefore, the pneumatic feed setting should be set to “Off”.
6.
Disconnect the main air from the pneumatic valve (6).
7.
Insert the 4mm hose into the right output (normally open) side of the pneumatic valve (7).
8.
Plug the fitting (8) on the other end of the 4mm hose into the quick connect on the applicator (9).
9.
Connect the main air and turn on the pneumatic valve switch (10).
Confirm clearance
10.
After the applicator is mounted and before ferrules are loaded, using the press jog
buttons to jog the press through a few cycles to ensure the tooling is
loaded correctly.
CAUTION
Always verify proper installation by first cycling the press slowly!
To prevent tooling damage, whenever any applicator is loaded into a press, the press should be cycled slowly or
manually to ensure the tooling will not crash.
7
8
9
1
4
3
6
10
5
2