background image

Quick Start Guide | Uni-M Panduit Ferrule Applicator in UniCrimp 200

 

Edition 1.4P (09-2019) 

www.schleuniger-na.com

 

1

3

 

This document is intended to assist users of the Uni-M ferrule applicator on setup and minor adjustments when used with 

Panduit strip form ferrules

.  The 

press used in this example is the UniCrimp 200 with pneumatic kit. Other presses should provide comparable results; however, split cycle function is 
required on the press.   

Applicators 

Applicator  

Wire Size  

Inserter Kit  

Funnel I.D. 

Crimp Height  

Index 

Uni-M 1516 

20AWG / 0.50mm

2

 

K008701  

2.4mm / 0.09” 

0.83mm / 0.033” 

2.0 

18 AWG / 0.75mm

2

 

K008175 

2.8mm / 0.11” 

0.94 – 1.04mm / 0.037 - 0.041” 

2.1 

18AWG / 1.0mm

2

 

K006667  

3.3mm / 0.13”

 

0.99 – 1.02mm / 0.039 - 0.040” 

2.1 

16 AWG / 1.5mm

2

 

1.25 – 1.27mm / 0.049 - 0.050” 

1.7 

14 AWG / 2.5mm

2

 

K008585 

3.6mm / 0.14” 

1.55 – 1.80mm / 0.061 - 0.071 

1.6 

Installing the applicator into the press 

Mounting 

1.

 

Release the base plate clamping lever (1) by lowering it completely until it comes to a stop.  

2.

 

Place the upper ram bolt (2) of the applicator into the press ram coupling (3) and lower the 
applicator until the base rests on the bottom base plate (4). Be sure that the upper ram bolt (2) 
remains in the ram coupling (3).  

3.

 

Lift the clamping lever (1) to lock the applicator into position. Firmly grasp the applicator and try to 
move it to ensure it is secure.  

4.

 

Remove the red tooling protection ring (5) if it is still installed.  
 

NOTE:

 Be sure to install the protection ring whenever the applicator is 

not in use. This part is very important to prevent damage to the tooling 
when the applicator is not in use. 

 

 

Air connection 

5.

 

The “Pneum Valve” setting in the interface “Functions” menu should be set to “Off”. Although the applicator requires air, the feed timing is 
handled internally in the applicator. Therefore, the pneumatic feed setting should be set to “Off”.  

6.

 

Disconnect the main air from the pneumatic valve (6).  

7.

 

Insert the 4mm hose into the right output (normally open) side of the pneumatic valve (7).  

8.

 

Plug the fitting (8) on the other end of the 4mm hose into the quick connect on the applicator (9).  

9.

 

Connect the main air and turn on the pneumatic valve switch (10).  

Confirm clearance 

10.

 

After the applicator is mounted and before ferrules are loaded, using the press jog 
buttons                      to jog the press through a few cycles to ensure the tooling is 
loaded correctly.  

 

 

CAUTION

 

Always verify proper installation by first cycling the press slowly!

 

To prevent tooling damage, whenever any applicator is loaded into a press, the press should be cycled slowly or 
manually to ensure the tooling will not crash.

 

 

10 

Reviews: