Form 55005 Rev. B
09-25-2001
5
CM5500 COMPUTER MANAGED MORTISE LOCK
INSTALLATION MANUAL
LOCK CASE
#12
COMBINATION
SCREWS
IF UNIT HAS PRIVACY FEATURE
,
FEED WIRE THROUGH CAVITY
AND OUT
3/4”
HOLE AS LOCK
CASE IS INSERTED
.
DO NOT
PINCH WIRES BETWEEN PARTS
.
4. INSTALL STRIKE BOX AND STRIKE:
5. INSTALL LOCK CASE:
Install lock case into edge of door. If the lock has the Privacy option, feed the wire harness though the 3/4” hole as shown
below. Secure to door with #12-24 combination screws.
IMPORTANT!
Strike included with lock MUST be
used for proper operation of mortise
lockset.