background image

6.

Back of 

Lock

Battery cover

10 key button

- registration of PIN codes 

LED indicator (locking status)

fl

 ickering (locked correctly)

fl

 ickering with alarm sound

  (abnormal locking status)

Manual locking button

- locks the door manually in     

manual locking mode

Fixing screw

Door handle

- panic release type

- can be used at any time

Privacy switch

- to set privacy mode

Low voltage indicator

- when the lamp 

fl

 ickers

and alarm sounds batteries 

should be replaced

R/C button

- registration of card/fob

Batteries

- 8 pieces

- 1.5v, AA, LR6 alkaline

Summary of Contents for ALLEGION S-6000

Page 1: ...S 6000 DIGITAL TOUCHPAD DOOR LOCK USER MANUAL DIGITAL D ...

Page 2: ...tice lock Auto lock Auto re lock function When the door is closed the lock engages automatically If users do not open the door after unlocking it the lock will re engage automatically Privacy function When privacy function is activated the door cannot be opened from outside even with the registered card fob or entry code Excessive force alarm If excessive force is used to try to bypass the lock th...

Page 3: ...ed skin area with soap and water immediately Do not clean the product with flammable materials such as alcohol benzene or thinners Such materials may damage the surface of the lock or cause a fire Batteries should not be exposed directly to heat sources or submerged in water because they may leak or explode resulting in severe damage Do not use damaged batteries Do not allow the battery electrodes...

Page 4: ...o manual locking system 9 Opening door from outside 10 Locking door from outside 11 Opening Locking Door From the Inside 12 Applications Privacy function 13 Auto locking function 14 Auto relocking function 14 Alarm warning functions 15 System reset 16 Setting volume level 17 User Manual Index Registering entry PINs 18 Registering cards fobs 19 Deleting entry PINs 19 Registering Remote Key 20 ...

Page 5: ...patch Key 3x User manual Includes warranty form Installation template For door preparation Batteries 8 pieces 1 5v AA LR6 alkaline Handle shaft 40 50mm thick door 89 W X 12 H X 12 D mm stop ring Handle shaft 50 90mm thick door 126 9 W X 12 H X 12 D mm stop ring Screws 5 x 30mm 4 of each for back cover 5 x 24mm 2 of each for inner lower part 5 x 8mm 2 of each for inner upper part 3 16 x 1 2 4ea for...

Page 6: ...Lock Touch type numeric pad enter PIN to operate lock Door handle Mechanical key override Battery replacement indicator replace batteries when this lamp begins to flicker Card fob touch plate External power supply ...

Page 7: ...ormal locking status Manual locking button locks the door manually in manual locking mode Fixing screw Door handle panic release type can be used at any time Privacy switch to set privacy mode Low voltage indicator when the lamp flickers and alarm sounds batteries should be replaced R C button registration of card fob Batteries 8 pieces 1 5v AA LR6 alkaline ...

Page 8: ... day Battery life can vary depending on battery s manufacturer production date installation environment and usage frequency Second hand batteries and or the use of batteries other than those specified is likely to cause a malfunction Do not use rechargeable batteries as battery leakage may occur Check batteries at least every 6 months and if there is any leakage replace with new batteries Battery ...

Page 9: ...ained via PIN card fob or fingerprint The batteries in the back of the lock can then be replaced see p 7 Front pad will not illuminate when batteries are exhausted Open cover directly beneath front door handle Touch terminals with 9V battery place and on either terminal Access via PIN or card fob Open cover directly beneath front door handle Insert manual override key and rotate Door handle can no...

Page 10: ...sequence This will prevent others from seeing your PIN code Press to enter Auto Manual Locking How to set auto manual locking system In auto locking mode door will be locked automatically after it is closed In manual locking mode the door is locked by pressing the manual lock button after the door is closed Touch the front pad Press Input user PIN Touch card fob Press Press 5 for auto locking mode...

Page 11: ...e de activated Touch the front pad Enter PIN code e g 1234 Press Pull down the handle and open Opening the door using card fob 1 Touch the registered card fob to contact point in centre of keypad 2 Pull down the handle and open the door Open the door with the sound muted Press the front pad with finger tip for 3 seconds Enter PIN code e g 1234 Card fob or fingerprint can also be used Press and the...

Page 12: ...ed If the door is not closed correctly it will not be able to lock and an alarm will sound If the alarm sounds please ensure that the door is closed correctly Locking the door in manual locking mode Close the door and touch the front pad Press 0 and the door will lock NOTE In manual locking mode door will not lock automatically Confirm the the door is closed locked by pull down the handle ...

Page 13: ... the inside Auto locking mode Manual locking mode When the door is closed the door will lock and the unit will emit a sound After closing the door press manual lock button and the door will lock The lock will emit a sound Flickering blue lamp shows lock is activated Flickering blue lamp shows lock is activated NOTE Before closing the door make sure that the deadbolt is not extended If the door is ...

Page 14: ... mode the door handle is still able to be used from the inside When the door handle is used from the inside privacy mode is deactivated The lock can be unlocked from the outside with the mechanical key even when privacy mode is on Privacy mode ON Privacy mode OFF Door cannot be unlocked from the outside Normal operation Door can be unlocked from the outside Red Green ...

Page 15: ...d the unit will emit a noise When door is locked the unit will emit a noise Auto re locking system Door is unlocked but the door is not opened After 7 seconds the door will be re locked to protect the property NOTE The auto relocking system cannot be deactivated ...

Page 16: ...the following situations Alarm will cease to sound after one minute Preventing forced entry If an attempt is made to force the door or lock open the unit will emit a strong alarm sound for one minute Follow the instructions below to stop the alarm sounding 1 Touch card fob 2 Enter PIN Press Enter PIN code e g 1234 Press 5 incorrect PIN entries 5 unregistered card fob swipes ...

Page 17: ... System Reset The unit can be reset to its factory settings by following these steps 1 Open battery cover 2 Hold down both the 10KEY and R C buttons for 3 seconds 3 Press 0 keys all data will be deleted 0 ...

Page 18: ... from ranging from mute to maximum Touch the front pad Press Input user PIN Touch card fob Press Press 2 Volume down Press 3 Volume up Press 1 Max volume Press 0 Mute NOTE In mute status keypad lamp will flicker when PIN is entered Once volume has been set pull down handle and close the door ...

Page 19: ...es can be registered with 4 to 12 digits each Previous PIN code s are deleted automatically with registration of new PIN code s Set up or delete new PIN codes when the door is open to prevent unintentional locking After changing a PIN code or entering a new PIN code verify it by unlocking the door with the new PIN code OPTIONAL Add additional PIN codes if required one at a time Press to add anothe...

Page 20: ...be registered Press button to complete registration How to delete cards and fobs Open battery cover and press R C Press 0 keys all data will be deleted NOTE Previous card fob memory is deleted automatically after registration of new card s fobs s Max 20 cards fobs can be registered For higher security please use cards fobs which are supplied by Schlage 0 ...

Page 21: ...ys will be deleted automatically Once the remote key is operated for more than 1 000 times when out of range remote key will no longer work If the operating distance of remote key is shortened with dim light or not working entirely please replace the battery ensure correct position of Registering RemoteKey Open battery cover and press R C Press any button on remote key For registration of several ...

Page 22: ...MEMO ...

Page 23: ......

Page 24: ... Australia Pty Ltd Phone 1800 098 094 www allegion com au Allegion New Zealand Limited Phone 0800 477 869 www allegion co nz Allegion South East Asia Phone 65 6488 2562 www allegion com S 6000 USER MANUAL 03 17 ...

Reviews: