background image

Instruction Guide  

ICID Double Wall Adjustable Starter Section

  

  Schiedel Chimney Systems Ltd. 

Crowther Estate 

Washington 

Tyne & Wear NE38 0AQ 

Tel. 0191 4161150 

Follow SchiedelUK 

  

  

  

 

Visit our website: 

Schiedel.co.uk

 

 

 

 

INSTRUCTION TO ALLOW REMOVAL  

OF STOVE FOR SERVICING 

 

1.  Slide adjustable case up 

inside the outer wall of the 
chimney.  

 

2.  Remove two loose insulation 

strips and keep to one side. 

 

3.  Loosen the locking band on 

the liner using the quick 
release clip (retain the 
locking band to one side). 

 

4.  Break the fire cement seal 

between the appliance 
spigot and chimney liner. 

 

5.  Slide the liner spigot up 

inside the chimney until clear 
of appliance spigot. 

 

6.  Remove appliance.

 

 

 

 

 

RE-INSTALLATION OF STOVE 

 

 

1.  Position stove spigot 

immediately beneath liner 
spigot of chimney. 

 

2.  Slide locking band into place 

around the joint on the liner, 
but do not tighten. 

 

3.  Slide liner spigot down inside 

the appliance spigot and seal 
using the fire cement or 
similar. 

 

4.  Now tighten the bolt on the 

locking band around the joint 
of the liner.

 

 

 

5.  Position narrower strip of 

insulation around the locking 
band with joint to the rear. 

 

6.  Slide adjustable cover down 

5mm past insulation. Position 
final insulation around spigot 
with joint to the the rear. 

 

7.  Slide adjustable case down 

over the insulation to cover 
the appliance spigot. 

 

 