18
Error messages will disapear immediately from the display when the control level is released or the fault
is eliminated. This means no waiting times for a restart.
If the table top model is used without a footswitch reset of the error messages by simultaneously
press and hold the reset touch fields Menu + + . A full reset can be done by pressing the touch fields
+ for 2 sec., or by disconnecting the mains supply.
If an error cannot be removed following the above description, please contact an authorised service partner
or Schick directly.
Exception:
14. Possible error messages
The
control unit has an intelligent control electronics system which
recognises possible defects and can display them with an error code on the control unit.
If there is a defect, this is shown with a flashing red light on the controls satellites, with a flashing red
SCHICK-logo on the
control unit and with an error message with the following format
"E xxyy".
Example:
Error code: E 0201 - no motor connected
Error code
Error description
Error removal
E 0201
no motor connected
Check whether handpiece is correctly connected
(motor output 1 / motor output 2)
E 0801
motor overload
reduce pressure to the tool
E 0802
cable break
Remove motorcable
motor blocked
Check if chuck is closed, make sure that the shaft can be
easiliy moved
general
errror
unit flashes red, no display at the
satellite
Check cabel satellite
15. Set up suggestions for the electric wax knife
The heating power of the electric wax knife can be ajusted from level 1 to 20.
The following set up suggestions are based on the Schick DesignWax and can be used as an example
for individual adjustments.
Wax
Set up
Working temperature
Cervical wax lila
Level 10
approx. 125°C
Ceramic wax yellow
Level 11-12
approx. 130° - 135°C
Modelling wax grey
Level 15
approx. 140°C
Milling wax green
Level 15-17
approx. 140° - 150°C
14.1 Reset after error message