Page -8-
ASSEMBLY INSTRUCTIONS
Step 9
FIRST ASSEMBLY CHECK FOR LEAKS
The heater must be leak tested before any further assembly is done. Use only a soap and water solution.
DO NOT USE FLAME
.
Turn the Control Knob to the "OFF" position. Securely connect the Regulator to the Propane Gas Cylinder. Open
the Propane Cylinder valve. Apply a dishwashing soap (1-part) and water solution (3-parts) to the connection at the
Manifold and Burner & Control Assembly. Bubbles will form if the connection is leaking. In the case of any leaks, turn
off the Propane Cylinder valve, remove the Manifold, and check and clean connection. Reconnect the Manifold and leak
test again. If the leak persists, do not return heater to the store. Please call toll-free 1-888-619-7060 or e-mail
[email protected] for assistance and advice.
Upon completion of the leak test, and there is no sign of a leak, turn off the Propane Cylinder Valve and disconnect
the Regulator from the Propane Gas Cylinder then remove the Propane Gas Cylinder and continue to the next step.
Figure 11
Step 9
Attach Pole to Burner & Control Assembly (Figure 11).
Align the 3 holes; insert (3) small bolts and tighten
using #2 Philips head screwdriver.
Figure 12
Step 10
Attach Manifold fixing plate to Pole Support
(Figure 12).
1. Look underneath post support. There will be a threaded
hole to mount manifold fixing plate.
2. Align the holes on manifold fixing plate with the
threaded holes on the pole support.
3. Make sure manifold fixing plate is facing downward.
(Figure 12).
4. Use (1) medium bolt to tighten manifold fixing plate with
the post support using #2 Philips head screwdriver.
5. Turn the manifold fixing plate so it will hold the manifold
in place.
6. Tighten the medium bolt so the manifold fixing plate will
not move.
7. Slide cylinder cover into place.
Models
SPC-54PHW SPC-54PHB SPC-54PHT SPC-55PHS
Summary of Contents for SPC-54PHB
Page 14: ......