OPERATING INSTRUCTIONS
HEATER
HEATERMODEL 80-FAP
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
!
PROPANE
CONSTRUCTION
National-Riverside
Universal
MODEL SPC-150T
SPC
ALL-PRO
FORCED AIR
150,000 BTU/HR
HEATER SPECIFICATIONS - 150
Type of Gas
For Use with Propane Gas Only
Input Rating
150,000 BTU/hr
Fuel Consumption
7 Lbs/hr
Gas Supply Pressure
to Regulator
Max: Bottle Pressure
Min: 5 psig
Regulator Out
11" W.C.
Fuel Orifice Size
1.00 mm Drill - 18 Holes
Electrical Input
115V, 60Hz 10, 4a
Minimum Operating Voltage
100V
Fan
3000 rpm, 450 cfm
Average Air Temp Rise
Approx. 300
o
F
Ignition
Direct Spark, Interrupted Type
Primary Flame Control
Solid State, 10-15 second Timing
High Temperature Limit Control
240
o
F
Minimum Ambient Temp. Rating
0
o
F
Size (Length x Width x Height)
26" x 9" x 16"
New Weight
32 lbs.
Shipping Weight
34 lbs.