15. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Possible cause
Remedy
The compressor does
not start.
Mains voltage is not available.
Check the cable, mains plug, fuse and
socket.
Mains voltage is too low.
Make sure that the extension cable is not
too long. Use an extension cable with
large enough wires.
Outside temperature is too low.
Never operate with an outside temperature
of below +5 °C.
Motor is overheated.
Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is no
pressure.
The safety valve leaks.
Contact your local service centre. Only
allow qualified personnel to carry out
repairs.
The seals are damaged.
Check the seals and have any damaged
seals replaced by a service centre.
The drain screw for condensate
leaks.
Tighten the screw by hand. Check the seal
on the screw and replace if necessary.
The compressor
starts, pressure is
shown on the pressure
gauge, but the tools do
not start.
The hose connections have a leak.
Check the compressed air hose and tools
and replace if necessary.
A quick coupling has a leak.
Contact your local service centre. Only
allow qualified personnel to carry out
repairs.
Insufficient pressure set on the
pressure regulator.
Increase the set pressure with the
pressure regulator.
Summary of Contents for 5906140901
Page 2: ...www scheppach com 2 1 2 3 1 2 3 4 7 6 5 8 9 10 12 13 11 13 10 14 12 11 5 5a 5b 17...
Page 3: ...www scheppach com 3 4 5 6 7 8 9 9b 9a 9c 12 13 7 7b 7a 15 4 4d 9 4a 4c 4a 4b 4c 4d...
Page 4: ...www scheppach com 4 10 11 A 1a 1...
Page 104: ...www scheppach com 104 GARY OF 1524 CE...
Page 105: ...www scheppach com 105...
Page 106: ...www scheppach com 106...