www.scheppach.com
GB | 21
D
Digital display: Display of the
heating stage of the running
heating element. Always shows
the heating stage of the upper
element when it is in operation.
1
Connect the mains plug and it will sound a control
tone. The heater is in “Standby” mode, the On /
Off symbol (A) lights up green.
2
Press the “A” button on the remote control or
on the control panel. The light turns red and the
heater changes into operation. The heating tube
and LED light are preset to stage 3. (The heater
has a memory function and runs in the last se-
lected setting).
3
Press the “B” or “C” button and the correspond-
ing heating tube or light and the digital display
flash up for 5 seconds; press the same button to
adjust the heater or light while the power setting
is shown on the display “D”. After 5 seconds, the
flashing stops and the setting is completed.
4
Switch off the heating tube and the light by press
-
ing the “A” button. The heater now changes into
“Standby” mode.
m
Warning!
Always disconnect the heater from the
mains when it is not in use.
Folding out the heating boom (Fig 9, 10, 11)
The heating boom works in a vertical or horizontal po-
sition.
Open the heating boom according to the following in-
structions and close it in reverse order.
1
Unlock the heating boom (B) by pressing the two
releases (A) inwards at the same time.
2
Fold the heating boom (B) upwards and hook the
securing bracket (C) into the recess (D).
Electrical connection:
•
The product fulfils the requirements of EN 61000-3-
11 and may only be used at the following connection
points: This means that use of the product at any
freely selectable connection points is not allowed.
• Given unfavourable conditions in the power sup-
ply the product can cause the voltage to fluctuate
temporarily.
• The product is intended exclusively for use at con-
nection points that do not exceed a maximum permit-
ted mains impedance “Z” (Z
max
= 0.017 Ω), or
2. Lower the base plate cover (4) again.
3. Secure the base plate cover (4) to the underside
of the base plate (5) with the washers (7) and the
screws ST3,5x16 (8).
8.
Setup and operation
m
Attention!
Remove the transport retainers before using the de-
vice (Fig. 7)
Setting up
• The minimum distances (at top: 60 cm, at the side:
150 cm) must always be observed, regardless of
whether the heating boom is in a horizontal or ver-
tical position. The distance must be measured from
the surrounding objects to the nearest point of the
heater.
•
Always keep flammable material away from the
heater.
• Do not twist or kink the power cable.
• This heater has IP34 class protection and is suitable
for outdoor use. If you need an extension cable, the
cable and plug system must be waterproof.
•
Never operate the on/off switch with wet hands.
m
Attention!
The heater has an anti-tilt protection. If
the heater tilts or falls over, it switches off automatically.
Operation (Fig. 8)
Settings on the heater can be made via the control pan-
el on the device or using the remote control.
Symbol
Function
A
On/off button: Switching the
entire
radiant heater on and off
B
Upper heating element: Selective
switching on and off of the upper
heating element, as well as
setting of the intensity (stages
from 1 to 5)
C
Light: Switching the LED lamp on
and off and setting the brightness
(stages from 1 to 5)
Note: When the heating bracket
is folded in, only the upper LED
lamp lights up. When unfolded,
both LEDs light up.