SCHEIBER
Printed 09/99
IV
MAINTENANCE
BE CAREFUL :
-
If you replace a fuse, comply with the calibres given in the technical data. Any other value may damage the
charger.
-
Do not use the charger to charge some cells.
-
During the charge, lead-batteries have to be in a well-ventilated location.
-
Only connect the charger in a main socket with earth.
-
You MUST connect the input clamp « earth » in such a way to ensure a continuity of people protection by
the differential of the plug on which the vehicle is connected (in case of bad insulation of one of the
equipment connected to the BIP 230V uses) ; for this purpose use the terminal delivered with the
accessories).
-
If cables are modified and cable-grips cutted, once new wiring is finished you must change the cable-grips.
-
Regularly check that connections are in good state (well screwed) otherwise it can lead to an overheating of
the terminals.
V
TECHNICAL DATA :
Model
30.65100.84
Mains input voltage range and frequency
230V 50-60 Hz
Maximum consumption on mains
1 A
Maximum charging current
10A
Constant voltage at the end of charging
13,7V +/- 0,1V
Number of uses 230V outputs
8
Number of uses outputs 12V
9
Number of spaces for circuits breakers
4
Calibre of fuse 1
5 A
Calibre of fuse 2
7,5 A
Calibre of fuse 3
10 A
Calibre of fuse 4
10 A
Calibre of fuse 5
15 A
Calibre of fuse 6
15 A
Accepted batteries
Rechargeable 12V gel batteries or free electrolytes
Recommended batteries’capacity
70 to 105 Ah
Size
205 x 205 x 105 mm
Weight
3,5 kg
Box
Fireproof and self-extinguishing ABS
Operating temperature range
Maximum ambient temperature 35 °C
Transformer protected by termic circuit-breaker.
SPECIFICATIONS:
This BIP-charger is part of class II.
IU Charge type :
Time
13,7V
Voltage
Full load
Float