V)      TECHNISCHE ANGABEN 
 

Modelle  

30.65100.00 

    Versorgungsspannung 

230V 50-60 Hz 

240V 50-60 Hz 

    Max. Ladestrom 

10 A 

6A permanent 

10 A intermittent  

    Max. Netzstrom 

1 A 

    Ladespannung 

13,7 V +/- 0,1V 

    Ausgang 230V 

    Ausgang 12V 

    Stellen für die Sicherungsautomaten  

    Sicherung 1 

5 A 

    Sicherung 2 

7,5 A 

    Sicherung 3 

10 A 

    Sicherung 4 

10 A 

    Sicherung 5 

15 A 

    Sicherung 6 

15 A 

    Zulässige Batterietypen 

       Batterien 12 V( 6 Elementen) mit Gel oder Freier Elektrolyt 

    Zulässige Batteriegrössen 

70 bis 105 Ah 

    Abmessung   

205 x 205 x 105 mm 

    Gewicht  

3,5 Kg 

    Box  

ABS feuer gesichert und selbstfeuerlöschende 

    Betriebstemperatur 
     

Max. Benutzungtemperatur 35°C 

Transformator gesichert durch thermische Sicherung 

 
VI)     BESONDERHEITEN 
 

Dieser Gerät sind von Klasse II. 
Durch  seiner  Lauf  prinzip,  kann  das  Ladegerät  permanent  am  Netz  ansgeschlossen  bleiben.  Für 
Freier  Elektrolytbatterien,  prüfen  Sie  regelmassig  das  Elektrolytniveau.  Je  nach  die  Älte  und 
Technologie der Batterie, erfolgt einen Elektrolytverbrauch. 
 
 
 

 

 

Ladekennlinie IU 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 

Zeit 

13,7V 

 

Spannung 

Ladung 

 

Wartungsladung 

Summary of Contents for 30.65100.00

Page 1: ...Le BIP Bo tier d interconnexions et de protections chargeur permet de recharger la batterie tout en continuant alimenter normalement les circuits d utilisations 12V via la batterie et les circuits d u...

Page 2: ...e d alimentation 230V est endommag il doit tre remplac par notre service apr s vente ou une personne ayant les qualification requises pour cette op ration Si la longueur de c ble aller et retour et es...

Page 3: ...ittent Consommation en charge maxi sur le r seau 1 A Tension constante de fin de charge 13 7 V 0 1V Nombre de sortie utilisation 230V 8 Nombre de sortie utilisation 12V 9 Nombre de module disponible p...

Page 4: ...kaging within the reach of a children or a non responsible person If the product falls or suffers a severe impact please contact immediately a qualified person to ensure that the apparatus still opera...

Page 5: ...disconnecting the device set the mains switch to OFF and unplug from the mains It must always be within hand reach when 230VAC supply wire is damaged it must be replaced by our after sales department...

Page 6: ...charger Do not use the charger to charge some cells During the charge lead batteries have to be in a well ventilated location Only connect the charger in a main socket with earth You MUST connect the...

Page 7: ...t the end of charging 13 7VDC 0 1V Number of uses outputs 230V 8 Number of uses outputs 12V 9 Number of spaces for circuits breakers 4 Calibre of fuse 1 5 A Calibre of fuse 2 7 5 A Calibre of fuse 3 1...

Page 8: ...auchsbeschreibung des Ger ts Benutzen Sie das Ger t f r keine anderen Zwecke als die f r die es bestimmt ist Vermeiden Sie St rze und heftige Schl ge sind solche aufgetreten wenden Sie sich sofort an...

Page 9: ...ksichtigen siehe Kapitel Kabelsektion die Kabel ordungsgem ss isolieren die Kabel so verlegen dass sie nicht besch digt werden k nnen Die Spannungsabschaltung erfolgt bei diesem Apparat ber Ausstecken...

Page 10: ...die St rke der Sicherung beachten die in der Tabelle HAUPTMERKMALE angegeben ist Jegliche Abweichung k nnte das Ladeger t besch digen Regelm ssig die ordnungdgem sse Befestigung der Anschl sse berpr...

Page 11: ...cherung 2 7 5 A Sicherung 3 10 A Sicherung 4 10 A Sicherung 5 15 A Sicherung 6 15 A Zul ssige Batterietypen Batterien 12 V 6 Elementen mit Gel oder Freier Elektrolyt Zul ssige Batteriegr ssen 70 bis 1...

Page 12: ...IBER will not be held responsible for direct damages or damages not due to the normal use of the equipment In case of a dispute arising between the parties the case shall be submitted to the French Ri...

Reviews: