background image

Date: 20.01.2010

E

Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt--gmbh.de

811.419 BA / EN

Instruction Manual

Electrobloc

EBL 99 K

EBL 99 K with OVP

Table of contents

1

Safety information

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1

Meaning of safety symbols

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2

General safety information

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Introduction

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Operation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1

Starting up the System

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.2

Changing the Battery

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.3

System Faults

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.4

Closing down the System

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Application and Functions in Detail

7

. . . . . . . . . . . . . . . . . . . . . . . .

4.1

Battery Functions

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2

Additional Functions

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Maintenance

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for Electrobloc EBL 99 K Series

Page 1: ...ctrobloc EBL 99 K EBL 99 K with OVP Table of contents 1 Safety information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Starting up the System 3 3 2 Changing the Battery 4 3 3 System Faults 5 3 4 Closing down the System 6 4 Application and Functions in Detail 7 4 1 Battery Functions 8 4 2 Additional Functions 9 5 Maintenance 9 Appendix 10 ...

Page 2: ...cal faults which may impact personal safety or the safety of the device must be rectified immediately by qualified personnel Y DANGER 230V mains voltage carrying parts Danger of death due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate from the power supply F Ensure that no liqu...

Page 3: ...use exception the battery cut off switch should be disabled when the vehicle is not in use see Section 3 4 One off settings only have to be configured when the battery type is chan ged lead acid or lead gel during initial start up or when retrofitting acces sories see Section 3 2 and the assembly instructions The EBL 99 K with OVP electrobloc is suitable for all applications in which the danger of...

Page 4: ...l lead gel or lead acid batteries Do not use any unsuitable bat tery types Y Normally only batteries of the same type and capacity should be used i e same as those installed by the manufacturer Y It is possible to swap lead acid batteries with lead gel batteries However swapping from lead gel batteries to lead acid batteries is only possible in certain cases Contact the vehicle manufacturer for mo...

Page 5: ...13 3 V Too many consumers are switched on Switch off any consumers not required Defective electrobloc Contact the customer service department Living area battery is overcharged during 230V operation battery voltage constantly above 14 5 V Defective electrobloc Contact the customer service department Starter battery is not No mains voltage Switch on the automatic Starter battery is not charged duri...

Page 6: ...theless Y If the automatic shutdown mechanism of the battery monitor is triggered fully charge the living area battery 3 4 Closing down the system The battery is isolated by switching off the battery cut off switch Y ATTENTION Total discharge Damage to the living area battery F Fully charge the living area battery before and after closing down the system Connect vehicle to the mains with an 80Ah b...

Page 7: ...a battery monitoring module F Control and monitoring functions The EBL 99 K with OVP electrobloc contains in addition F overvoltage protection OVP which isolates the electrobloc from the mains in the event of sudden voltage peaks in the 230V supply An IT or LT control and switch panel must be connected for operation These devices control the electrical functions in the vehicle s living area inc lu...

Page 8: ...Starter battery Charging current float charge max 2A The battery monitor compares the current of the living area battery to a refe rence current As soon as the battery current drops below 10 5V all 12V consumers are switched off via main switch relays 1 and 2 Only the frost protection valve continues to be powered The automatic disconnector is not triggered by short term low voltage shor ter than ...

Page 9: ...ing This feature provides an automatic max 2 A float charge for the starter bat tery when the 230V mains is connected to the electrobloc 5 Maintenance The EBL 99 electrobloc is maintenance free Clean the electrobloc with a soft slightly damp cloth and mild detergent Ne ver use spirit thinners or similar substances Do not allow liquids to enter the electrobloc No part of this manual may be reproduc...

Page 10: ... Declaration of Conformity is available for reference at any time Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 88677 Markdorf Germany B Special fittings accessories Schaudt IT LT switch panel required for operation Schaudt battery charger LAS with max 18 A charge current including suitable connection cable MNL Schaudt Solar charge regulator type LR for solar modules with a total cur rent...

Page 11: ...port to the manufacturer Device type _______________________ Item no _______________________ Vehicle Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No Following fault has occurred please tick Electrical consumers do not work which please specify below Switching on and off not possible Persistent fault Intermittent fault loose contact Other re...

Page 12: ...lve heating and floor light steps 5 Connection IT LT control and switch panel 6 Connection block reserve 7 Connection block solar regulator 8 Connection block additional charger 9 Connection block TV pump consumers 10 Selector switch acid gel battery 11 Flat vehicle fuses 12 Battery cut off switch 13 Housing 14 Assembly flaps 15 Sticker OVP only for EBL 99 K with OVP Starter Battery Negative Batte...

Page 13: ...om batt Batt 2 E20 3F MNL socket cap 3F block 6 A E charge 3 1 2 3 1 2 TV HS relay 60A Spare 5 MNL socket cap 2F block 7 Fridge Negative starter battery for refrigerator Negative refrigerator Compressor AES refrigerator Absorb refrigerator Negative living area batt sensor Minus sensor living area battery batt 2 Module BW 99 2 Cond pl KPL EBL 99 1 Step Floor light Solar cell Spare 2 Spare 3 Spare 4...

Page 14: ...Instruction Manual for Electrobloc EBL 99 K EBL 99 K with OVP 14 Date 20 01 2010 811 419 BA EN blank page ...

Reviews: