4.1

Battery functions

6-cell lead acid or lead gel batteries, 55 Ah and above

Simultaneous charging of the starter battery and the living area battery via

the alternator, parallel connection of the batteries via a cut-off relay

The battery cut-off (at the battery cut-off switch of the Electroblock, see Fig.

4, Pos. 15, see also section 3.4) isolates the following connections from the

living area battery:

F

all 12 V consumers

F

the frost protection valve

This prevents slow discharge of the living area battery by the standby cur-

rent during shutdown of the vehicle (discharge with approx. 4 Ah in month).

The batteries can still be charged using the Electroblock, the alternator, an

auxiliary charging unit or the solar charge regulator, even when the battery

cut-off switch is switched off.

The switching option provided by the battery selector switch ensures opti-

mum charging of the two battery types, lead gel and lead acid.

The battery monitor of the DT ... control and switch panel constantly moni-

tors the living area battery with dynamic voltage threshold. The cut-off point

is ”earlier” for lower discharge currents than for larger currents. This provi-

des improved total discharge protection. Monitoring is also performed in the

switched-off state. A warning message is displayed below 12.0 V (depen-

dent on current drain).

If the voltage of the living area battery sinks further, falling below 10.5V, the

battery monitor immediately switches off all 12V consumers. The control and

display panel also switches itself off. Only the frost protection valve conti-

nues to be powered (so it stays closed). Before switch-off, all switch states

and the value of the battery capacity are stored and restored after power-on.

If an overload or an insufficiently charged living area battery causes the vol-

tage to fall so low that the automatic disconnector is triggered, any non-es-

sential consumers should be switched off.

If need be, the 12V supply can begin operation for a short time. In this case

the 12 V main switch on the DT ... control and switch panel must be swit-

ched on.

However, if the battery voltage remains below 11.0 V, the 12 V power supply

can not be turned back on.

Fully charge the living area battery as soon as possible. For more informa-

tion, see the ”Battery voltages” description in the relevant DT ... control and

switch panel instruction manual.

Suitable batteries

Battery charging

whilst moving

Battery isolation

Battery selector switch

Battery monitor with

automatic disconnect

Summary of Contents for EBL 101 C with OVP

Page 1: ...BL 101 C with OVP Table of contents 1 Safety information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Switching system on off 3 3 2 Changing the battery 4 3 3 Operating faults 6 3 4 Closing down the system 7 4 Application and functions in detail 8 4 1 Battery functions 10 4 2 Additional functions 11 4 3 Use as an exchange device 11 5 Mainten...

Page 2: ... device must be rectified immediately by specialists Y DANGER Parts carrying 230V Risk of fatal injury due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged do not use the device and isolate it from the power supply F Ensure that no liquids enter the device F The mains connection line may only be replaced by an autho...

Page 3: ...ly use Initial settings are only required after the type of battery lead acid or lead gel has been changed or during commissioning or when upgrading with ac cessories see section 3 2 and EBL 101 D EBL 101 C with OVP installation instructions for details 3 1 Switching system on off Y ATTENTION Incorrect Electroblock settings Damage to connected devices Therefore prior to starting F Ensure the leisu...

Page 4: ...nnected devices F Do not operate solar regulator without battery connected Y If an original Schaudt solar regulator is used the solar current can be dis played on the control and display panel e g DT For this the control and display panel must be configured accordingly a PIN is required Ask your dealer for advice 3 2 Changing the battery Y ATTENTION Use of incorrect battery types or incorrectly ra...

Page 5: ... of the battery selector switch Damage to the battery F Move the battery selector switch to the correct position Disconnect the Electroblock from the mains before adjusting the battery selector switch Y When using AGM batteries moving the battery selector switch to the Lead Gel position is recommended Experience tells us that AGM batte ries are charged perfectly this way However suitability must b...

Page 6: ...he vehicle g g p ration battery voltage constantly below 13 3 V Have the mains voltage constantly below 13 3 V Have the mains voltage checked Defective Electroblock Call customer service Living area battery is over charged during 230V ope ration battery voltage constantly above 14 5 V Defective Electroblock Call customer service Starter battery is not char No mains voltage Switch on the automatic ...

Page 7: ...itch panel Defective fuse or wiring Check fuse and wiring Defective fuse or wiring Check fuse and wiring Defective Electroblock Call customer service The Electroblock cannot be operated from the DT Defective Electroblock Call customer service be operated from the DT control and switch pa nel Y The charging current is reduced automatically if the device becomes too hot due to excessive ambient temp...

Page 8: ...witch is switched off Fully charge the living area battery before closing down the system Remove the solar cell connector on the solar charge regulator Remove the clamps from the battery terminals Y The battery alarm is no longer active Y The frost protection valve opens for certain heater systems when the li ving area battery is isolated from the Electroblock via the battery cut off The boiler an...

Page 9: ...contains in addition F overvoltage protection OVP A DT control and switch panel must be connected for operation This de vice controls the electrical functions in the motorhome s living area as well as the accessories There are connections for an additional battery charger and a solar charge regulator Flat vehicle fuses protect the various circuits Exceptions here are the step and the frost protect...

Page 10: ...discharge currents than for larger currents This provi des improved total discharge protection Monitoring is also performed in the switched off state A warning message is displayed below 12 0 V depen dent on current drain If the voltage of the living area battery sinks further falling below 10 5V the battery monitor immediately switches off all 12V consumers The control and display panel also swit...

Page 11: ...on the solar charge regulator used either only the living area battery is charged or the living area battery and the starter battery 4 3 Use as an exchange device Electroblocks EBL 101 D and EBL 101 C with OVP can be used as ex change devices for the EBL 100 The plug and socket connections of the old device can all be used Some additional functions and plug connections of the EBL101 will however r...

Page 12: ...y of equipment from February 26th 2008 Schaudt GmbH Elektrotechnik Apparatebau Daimlerstrasse 5 88677 Markdorf Germany B Special fittings accessories Schaudt DT switch panel required for operation Schaudt battery charger LAS with max 18 A charge current including suitable connection cable MNL Schaudt Solar charge regulator type LR or LRS required if the solar current is to be displayed for solar m...

Page 13: ...mittent fault loose contact Other remarks E Technical details 230 V AC 10 47 to 63 Hz sinusoidal protection class I 1 9 A Depending on the control and switch panel approx 5 20 mA plus con sumption of controller electronics of refrigerator Measurement approx 10 minutes after disconnection from the mains F not connected to mains F 12 6 V battery voltage F Battery isolation not enabled F Control and ...

Page 14: ...tomatic changeover to trickle charge with constant 13 8V In the trickle charge phase the voltage at the output of the charging module is constant Start of a new charging cycle by switching over to main charge if the battery voltage falls below 13 8 V for more than 5 seconds when loaded Start of charge also for totally discharged batteries The internal charge module can also be operated without liv...

Page 15: ...nd switch panel 6 Connector DT control and switch panel 7 Connection block solar regulator measurement signal 8 Connection block reserve 9 Connection block solar regulator supply 10 Connection block additional charger 11 Connection block TV pump consumers 12 Selector switch acid gel battery 13 Self resetting step fuse internal 14 Flat vehicle fuses consumers 15 Battery cut off switch 16 AES refrig...

Page 16: ...9to DT digital panel MNL bush socket 5F BL2 MNL bush socket 4F BL1 MNL bush socket 5F BL8 D point Signal solar living area battery Signal solar starter battery nc nc nc nc Refrigerator lines must be lead to the battery poles without being connected to other battery supplies every 1 5 mm2 max 10 m Compressor AES refrigerator Absorber refrigerator D point Negative refrigerator D point TV Pump Circui...

Reviews: