Operating Instructions Booster WA 121545
6
Date: 21.09.2017
8200510 BA / EN
Charge current limitation
Specified by power limitation characteristics C1
to C4. The maximum charge current is reached
for the following voltages:
”Power
Reduct.”
No char-
ging when
Max. charge
current
Suitable for (recommendation):
C1
U
e
±
11.2V
U
e
²
11.8V
Without input voltage sensor:
EURO6-Generator with drop down voltage U
ab
²
12,6
V
C2
U
e
±
11.8V
U
e
²
12.4V
With input voltage sensor:
EURO6-Generator with drop down voltage U
ab
²
12,6
V
C3
U
e
±
12.0V
U
e
²
12.6V
With input voltage sensor:
EURO6-Generator with drop down voltage U
ab
²
12,6
8 Medium
loading of the starter battery circuit
C4
U
e
±
12.6V
U
e
²
13.2V
With input voltage sensor:
Conventional generator, low loading of the starter battery circuit
Power limitation characteristics C1 to C4:
I
L
(A)
0
U
E
(V)
10
10,5
11
11,5
I
max
C1
C2
C3
C4
12
12,5
13
11,2
11,8
12,6
13,2
11,8
12,4 12,6
13,2
Fig. 1
Charge current limitation characteristics C1 to C4
Back current from battery
(after cooling)
”Engine OFF”:
Starter battery: < 0.1 mA
Leisure area battery: <
0.2mA
Control current
”Engine ON”:
D+ connector: < 1mA
5.2 Mechanical details
Connections
Batteries:
SPC16- or ISPC16 Phoenix plug
connector for connecting wires to
max. 16mm
2
(connector with ten-
sion clamps)
D+
Connector:
Rast 5; code 0G; 2-pin or 6.3 mm
AMP flat connector
SDTBUS
2 Lumberg pin rails
Type MSFQ, each 3-pin
Tempera-
ture sensor:
SB: VAL-U-LOK; 2-pin
WB: VAL-U-LOK; 4-pin
Type Tyco AMP 2-pin / 4-pin
Casing
Aluminium, 160 x 79 x 160 mm
(W x H x D, without attachment feed);
can be screwed to flat surface
(D = 186 mm including attachment feet)
Weight
Approx.
1,150 g
Installation position