9
2021-07-15 / V1.0
Contactors C320K/C320S – Installation and Maintenance Manual
Product information
4.3 Overview
C320K/1000
B
E
F
G
A
B
E
C
C
C
E
E
C
D
D
A Arcing chamber
B Main contacts: connection M8, torque 10 ... 12 Nm
C Base plate with 4 fastening holes for M5 screws, torque 2.3 ... 2.7 Nm
D Fixing lugs for bundling and fixing control wires with cable ties
E Auxiliary switch S870 W1D1 t, flat plug connections 6.3 x 0.8 mm
(dependent on the design, up to 4 auxiliary switches per contactor are possible)
F Economy circuit for coil
G Coil terminal: cage clamp connection