Figure 50:
Test inlet on the siphon blocks VN180
Attention: In case of siphon block VN180 installation you
have to test all compartments and the additional suction
points at running engine.
7.3
Additional pressure measurement on VN115/87plus EX installations
Perform the functional and smoke test as shown in the previous chapters 'On board
test' and
‘Factory test with smoke generator’
.
Figure 51:
Manometer (not scope of
supply) connected to siphon
block VN180
Figure 52:
Manometer (not scope of
supply) connected to
header pipe
Then carry out a pressure measurement at the end of the suction system. The
engine including the oil pump must be at standstill.
Attention: You will only measure correct values with engine
and lube oil pump at standstill.
19 mm nut
17 mm nut
Adapter
Lock screw