3.
Insert the sensor into the shaft adapter, align the sensor with the hole circle of the supporting
tube, and tighten the screw connections (6x) crosswise.
4.
Tighten the central bolt to 25Nm, while counterholding the centring pin with a spanner (size
46).
5.
Loosen the bolts of the centring pin, press the centring pin down evenly using its set screws
and remove it.
6.
Put the brush in place on the shaft by pulling the black lever of the brush forward and turning
it
in
the direction of the shaft.
Figure 8: Alignment and installation - Part 2
7.
Connect sensor cable M12 (
“
hand-tight
”
, to approx. 50 cNm)
8.
Install the cover, making sure that the O-ring seal is seated correctly.
Figure 9: Final installation