![Schalk SMS 1 Quick Start Manual Download Page 6](http://html1.mh-extra.com/html/schalk/sms-1/sms-1_quick-start-manual_1210046006.webp)
Operating voltage
230 V 50/60Hz 10 %
Power consumption
approx. 0.66 W
Wind measuring range
10-70 km/h
Wind switching hysteresis
25 %
Wind response time
1s - 15s
Sun measuring range
Light intensity: 20000Lux - 100000Lux / Twilight: 1Lux - 70Lux
Sun switching hysteresis
Light intensity: 40 % / Twilight: 20%
Sun response time
10 min (user programmable)
Motor run time
90s (user programmable)
Relay switching dead time
0.6s
Sensor supply voltage
3.3 V DC (PELV)
Ambient temperature
-10°C to +45°C
Noise immunity
Compliant with IEC 0801-4 Level 3
Device protection
Compliant with IEC 0801-5 Level 3
Creepage distance and air gap
Compliant with VDE 0110 Gr. C/250 V
Insulating housing
Non-flammable VDE 0304 Part 3, Level FV 0
Installation orientation
Any
RAL colour
Grey 7035 / Green 6029
Relay output
2 NO contacts 4 A / 250 V AC
AC terminals
Female terminals with captive screws M3.0 (2x 1.5 mm² / 1x 2.5 mm²)
PELV terminals
Female terminals with captive screws M2 (1x 1.5 mm²)
Dimensions
43 x 43 x 18.5mm³
Relay output
2 floating NO contacts 10 A / 250 V AC
Mounting
Snap mount on standard 35-mm rail (EN 50022)
Terminals
Female terminals with captive screws M3.5 (2x 1.5 mm² / 1x 2.5 mm²)
Dimensions
18 x 88(45) x 58mm³
Wind sensor
Reed contact pulse transducer
Light sensor
LDR
Connecting cable
max. 50m (with 2 x 0.25 mm²)
Dimensions
ca. 60 x 80 x 180mm
3
Protection rating
IP33
Colour
White
Part no.
EAN
Type
Designation
SMSU19
SMS U1
Sensor-driven motor controller (wind/light), 230V AC (UP)
SMS109
SMS 1
Sensor-driven motor controller (wind/light), 230V AC (REB)
SWL200
SWL 2
Combined wind/light sensor with articulated mount
Motor controllers
www.schalk.de
M
otor
c
on
tro
lle
rs