Loosen filter clamp (pos. 4) and remove it along with shipping

brace. Press the particle filter unit (pos. 2) with the sealing rub-

ber pointing in the direction of the rear wall into the filter hous-

ing (pos. 1). Take care that the filter material is not irreparably

damaged. The VM pole braces (pos. 3) are placed on the filter

housing and fastened using the filter corner clamps (pos. 4).

The filter corner clamps are tightened firmly until the filter cell

has a tight fit. Care must be taken that the filter corner clamps

are tightened cross-wise to 4 Nm maximum. If required, a seal

leakage test can be carried out before mounting the air diffusers.

Shipping brace

Attention!
Before the particle filter unit can be inserted, the shipping
brace clamped by means of the filter clamps must be re-
moved!