Schaffner Group
User and Installation Manual
Output filter FN5420 and RWK5420
4/52
Performance Guarantee
The remaining voltage and current ripple at motor terminals is reduced to values <5% according to EN
61000-2-2.
ii.
Minimum system Requirements
The highest performance levels of the selected filter will be achieved when the following system condi-
tions are met:
|
Motor frequency: up to 60Hz without derating and up to 200Hz with derating (see section
2.4.2)
|
Maximum surrounding air temperature: 70°C for filter sizes 26 to 1'100A and 100°C for filter
sizes 2.3 to 18A, always with derating above 45°C.
|
Nominal voltage: ±10%
|
Voltage unbalance (at filter input): <3%
|
Maximum DC link voltage: 750VDC
iii.
Important user notice
Schaffner sine wave filters are designed for the operation on the output (motor) side of converters,
such as AC or DC motor drives. Filter suitability for a given application must be determined by the user
on a case by case basis. Schaffner will not assume liability for any consequential downtimes or dam-
ages resulting from use or application of Schaffner sine wave filters beyond their specifications.
Schaffner sine wave filters are not designed for single-phase or split-phase applications.