Schaffner Group
User and Installation Manual
Ecosine FS42842
25/43
16.1 Drilling pattern for wall mounted filters:
H
D
All dimensions in mm; 1 inch = 25.4mm
Note:
the numbers (e.g
. -10
) are in reference to the middle
part of the ecosine part number coding (e.g. FS42842
-10
-44)
2.1
Bolt selection
Schaffner recommends zinc coated hex ribbed flange steel
bolts. Respect filter weight for appropriate choice of bolts! Head
diameters must not exceed these dimensions:
M8: d
≤ 18.2mm, M10: d ≤ 21.2mm M12: d ≤ 25mm
16.2 Filter placement
1. Set bolts loose into wall, leave 5mm distance from head to
wall.
2. Lift filter with appropriate hoist, using lifting eye bolt
(attached in package)
– smallest types (up to 20kg) may be
lifted manually by two persons (no lifting eye bolt
applicable).
3. Place filter first onto lower bolts...
4. ...then position it through backplane head openings on upper
bolts.
5. Fix bolts with appropriate torque (depending upon the
material of the back plane and local standards).
Step 3: Wiring
3.1 Verify safe disconnection of all line side power.
Consult your local safety instructions.
d
4.
3.
FS42842
H
W
D
-10, -13, -16
370
140
M8
-24, -32, -38, -45
435
200
M10
-60, -75
500
225
M10
-90, -110
555
225
M10
-150, -180, -210,-260, -320
665
350
M12