background image

Daily cleaning 

SCA Plus / Cold Milk System

Schaerer Ltd. P.O. Box 

CAUTION!

User at risk!

In the beverage dispensing area, there is a danger of scalding due to hot water and steam.
Never reach under the dispensers while dispensing or cleaning.

See also "Safety instructions" and "Cleaning" in the operating instructions.

Press   -button ca. 4 sec.

Display: "Cleaning programme / 
empty gr. container".

Pull out the grounds container within
5 sec seconds and clean it.

Clean brewing chamber with a brush.

Insert the grounds container.

Option: Powder system

Display: "Check if mixer is in place".

 - Press the button.

"Cleaning programme / insert tab-
let“ appears on the display.

Open inlet for ground coffee.

Option 1:  With lid monitor

Insert cleaning tablets within 15 sec.

Option 2:  Without lid monitor

Insert cleaning tablet

 - Press the button.

Close the inlet.

Option 1: Without steam; without boiler 
rinse

Continue with step 4.

Option 2: With steam; with boiler rinse

Display: "Cleaning programme / hot 
rinsing".

Place a container (ca. 1 l capacity) un-
der the steam wand.

 - Press the button.

Hot rinsing running.

Option 1: Deactivated milk system

Cleaning started (see display for 
duration).

Continue with step 6.

Option 2: Activated milk system

Display: "Cleaning programme/
cleaning agent".

Open cooling unit doors.

Remove the milk container.

Fill Schaerer cleaning product into the
cleaning container. Dosage:

Single-chamber cleaning container:
100 ml

Two-chamber cleaning container:
100 ml per chamber. 

Single-chamber cleaning container for
Centre Milk: 200 ml 

Replace cleaning container (1).

Place hose / hoses in the container (2).

 - Press the button.

Cleaning is running (see display for 
duration).

Reviews: