www.schaerer.com
User Manual SCF - EN
05.2008 / Version 06
Software
Water Hardness/Capacity
On plumbed coffee machines with a constant water
supply (without anti-scale filter, optional), with Aquaflex
option and coffee machines with a water tank the water
hardness (carbonate hardness) is set here.
With fitted filter and constant water supply or with
Aquaflex option:
Filter capacity is set here.
(Filter capacity can be found in the anti-scale filter
documentation.)
Warm-Up Rinse
Here enter the setting as to whether the coffee machine
should rinse out the brewing unit with hot water after
heating up.
Recommended setting: active.
Foamer rinsing (optional)
Automatic foamer rinsing after the last beverage
dispensing with milk components.
Yes/No
Rinsing interval
The time elapsed between the last removal of a
beverage with milk in it and a foamer rinsing.
Recommended setting: 2 minutes.
Operating options
The following operating options are available.
Warm Up Button (active/inactive)
•
• Barista pad (active/inactive)
Second Level Toggle Pad (active/inactive)
•
ON/OFF button (direct/via PIN)
•
Menu pad (immediate/delayed)
•
If customers serve themselves
some functions can be switched
to inactive. The inactivated
pads will not be shown on the
ready to operate display.