Schaeffler Technologies
BA 68
37
Gateway configuration
Various interfaces are available for communication between
the gateway and Schaeffler IoT Hub.
Note
Normally there is no need to change the standard gateway settings,
but for certain installations it may be necessary to adapt or
change some of the standard settings. These settings should be
undertaken only by skilled personnel.
The following settings can be changed:
■
WiFi
■
LAN.
Initial login to gateway configurator
To reach the user interface of the gateway configurator using
a browser, proceed as follows:
Press the [
Configuration
] button on the gateway until the status
LED flashes blue.
The gateway is in configuration mode.
The gateway becomes a WiFi access point.
The name of the WiFi access point is “OPTIME
serial number
”,
whereby “
serial number
” is the serial number of the gateway.
The serial number is on the sticker on the side of the gateway.
Establish a WiFi connection between your computer or mobile
device and the WiFi access point. The WiFi password is
on the nameplate.
Open your browser and enter the IP address 192.168.0.1:3001.
If necessary, determine the TCP/IP values of the gateway if the
pre-set IP address does not work. This can happen if the device
was already connected to another network.
The drop-down menu opens and displays the setting options.
���
Button [
Configuration
]
���
Nameplate with WiFi password
Figure 21
Button on gateway
OP
TIME
1
2
0018D
88F
0018D
88F