Schaefer WayCool 1/3HP User Manual Download Page 15

Operation & Maintenance

REGULAR CLEANING

The frequency with which the WayCool

®

is cleaned will depend on the environment in which it is used. The more dirty the environment the

more often it will need cleaning. In most cases the WayCool

®

will need to be cleaned weekly.

Caution: The pads should be dry before you handle them, as they are stronger when dry than when they are wet and less
susceptible to damage. If they are wet, run the unit in the HIGH VENT position until they are dry. After cleaning, let the pads air
dry before you replace them.

1.

Turn the switch to OFF and unplug the unit.

2.

Remove the plastic retaining grates and check the pads for cleanliness. If they are dirty, remove and clean by spraying with a
garden hose, water only. If they are not dirty you will still need to remove the cooling pads to clean the inside of the unit. Dirty
cooling pads reduce the unit's effectiveness.

3.

Use a garden hose to rinse out the bottom and the inside of the unit. The dirt that accumulates is removed from the air during
operation, as the WayCool

®

unit also acts as an air filter.

4.

Remove the drain cap from the underside of the unit and let the unit drain completely. Rinse out any remaining dirt.

5.

Replace the drain cap (finger tighten only).

6.

Remove the pump discharge filter by unscrewing the top, removing the screen and rinsing it with a hose or under a tap. Replace the
filter screen and screw the top back on.

7.

Remove the pump filter from underneath the pump. Wash thoroughly with a hose. Compress filter and place back under the pump.

8.

Replace the cooling pads once they are dry and reinstall the plastic retaining grates.

Note: With proper use and regular cleaning, the cooling pads will last about two seasons. If you handle them wet and are
abusive, however, they will be easily damaged.  Refer to page 15 for recommended conditioning and cleaning chemicals.

NORMAL STARTUP

1.

Place the unit in the position where it will be run. Do not attempt to lift or move the unit once it is filled. Damage to the unit or a large
spill may occur.

Note: When you decide where to place the unit, make sure there are no obstructions in the way that will disrupt or block the
airflow.  Make sure the unit is level at all times.  Keep the unit at least three feet away from walls or other obstructions that will
interfere with airflow into the unit.

2.

Check to ensure the drain cap is in place and secure.

3.

Connect the garden hose to the brass hose adapter. Check that there is a washer in the hose connection's female end.

4.

Open the water supply valve and check that water enters the bottom through the float valve by removing one cooling pad on the
side with the water connection. Allow the unit to fill and check that the float valve completely shuts off the water.

5.

If you are manually filling, remove one or more cooling pads and fill the bottom with a bucket or hose.

6.

Visually monitor the filling operation to avoid overflowing and causing spill damage.  

7.

Plug the unit into an outlet.

8.

Adjust the blower duct to discharge the cool air in the desired direction and tighten the knob on the end of the threaded rod.

9.

Turn the switch to the pump only position and let it run for 5 - 10 minutes to saturate the cooling pads. Check that the pads are
saturated completely and there are no dry spots.

CAUTION: Do not run the pump without water in the bottom or you will damage the pump. Running the pump dry will void the
warranty on the pump.

10. Turn the switch to the High Cool or the Low Cool position to begin normal cooling operation.

NORMAL SHUTDOWN

1.

Turn the switch to the High Vent position, and let the unit run until the cooling pads are dry. This will maximize the life of the pads.

2.

Turn the switch to the OFF position. Unplug the unit if you are going to clean the pads or inspect the components.

3.

Shut off the water supply.

4.

Drain the bottom if you are going to clean it or store it.

5.

If the unit will be stored for the season, ensure the cooling pads are completely dry, and then remove them. Wrap them in plastic
bags or store them in a clean place where they will not be damaged or get dirty. The unit should be cleaned thoroughly before
storing.

13

Summary of Contents for WayCool 1/3HP

Page 1: ...Portable Evaporative Cooler WayCool 1 3HP Series USER S MANUAL...

Page 2: ...3 Normal Startup 13 Normal Shutdown 13 TROUBLESHOOTING 14 Cooling Pads not Wetting 14 Foaming 14 Line Clogs or Obstructions 14 Splattering out Front 14 Leaking out Bottom 14 Odor Control 14 Scale Buil...

Page 3: ...e cooling effect In an evaporative cooler the cellulose cooling pads take the place of your skin water instead of perspiration wets them and a fan moves the air The air blows across the cooling pads a...

Page 4: ...the right to make changes at any time without notice Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations Care should be taken to keep this informat...

Page 5: ...nd wear gloves when you reach under the frame to inspect the PVC pipes and mesh socks A GFCI Ground Fault Circuit Interrupter is recommended for use with this product If pads and grates are removed fo...

Page 6: ...e Pump Vane Type 210 GPH Gallons Per Hour Pump Filter Washable Polyethylene Filter Pump Discharge Filter 480 Micron Stainless Steel Reservoir Capacity 14 Gallons Optional Water Supply Standard Hose Co...

Page 7: ...tal eight sections to totally enclose the unit The blower is hung from the top of the frame and powered by a direct drive 1 3HP electric motor The blower draws room air through the cooling pads where...

Page 8: ...the bottom can also be manually filled with a hose or bucket if a hose connection is impractical Simply remove any of the plastic retaining grates and one of the cooling pad sections and place the ho...

Page 9: ...r flow to the cooling pads is reduced and performance decreases The clear filter housing is threaded and screws into the filter body for easy removal to access the screen Note A dirty water supply wil...

Page 10: ...when wet Always run the unit with the plastic retaining grates in place and handle them carefully when you clean them Crushed cells reduce the total airflow through the unit and therefore lowers it s...

Page 11: ...bare connections or you could be injured The power cord runs down the frame leg that has the control switch on the outside It exits the frame leg at the bottom and has a male plug that must be plugge...

Page 12: ...the pump is OFF Use this setting to quickly dry the cooling pads for removal and cleaning LOW COOL The blower runs at low speed and the pump is on Use this setting for low cooling loads HIGH COOL The...

Page 13: ...he air flowing in the same direction Do not direct other fans against the WayCool unit It will counter the WayCool s airflow and stop the cooling effect Obstructing the airflow from the WayCool unit s...

Page 14: ...bottom 6 Remove the cooling pads from all four sides of the unit Place a putty knife or large flat bladed screwdriver under the pad to lift it up then outward With one pad out the rest can be easily r...

Page 15: ...nce it is filled Damage to the unit or a large spill may occur Note When you decide where to place the unit make sure there are no obstructions in the way that will disrupt or block the airflow Make s...

Page 16: ...t hold on the unit s top cover 5 Remove the top cover and set it aside 6 Locate the four PVC pipes in the top metal channel Each PVC pipe is secured to the Y connector by a single screw Remove this sc...

Page 17: ...he pneumatic wheel options includes two locking and two non locking wheels Pneumatic wheels are designed to allow for easy rolling on rough or uneven surfaces 15 WayCool Water Condition is recommended...

Page 18: ...eed to be replaced 5 If the motor is not running the motor may have failed or there could be a wiring problem contact a certified electrician If the motor is determined to have failed it must be repla...

Page 19: ...umper labeled A into the L position on the switch 15 Cut the black wire from the power cord just below the blue connector and then strip of plastic from the black wire 16 Twist the bare end of this wi...

Page 20: ...arts To order replacement parts contact the dealer from whom you purchased your WayCool If you do not have that information please call Schaefer Ventilation Equipment at 800 779 3267 to locate a deale...

Page 21: ...rranty THERE IS NO WARRANTY OF MERCHANTABILITY AND THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF Products with warranty periods that exceed our standard one year warra...

Reviews: