SCE Enviro-Therm SCE-AC10200B460V3 User Manual Download Page 16

B

16

SAGINAW CONTROL & ENGINEERING  •  A/C USER MANUAL

back to top

17. Transportation & Storage

18. Parts Supplied

16. Maintenance & Cleaning

During transport and storage the cooling unit must be kept in the position marked on the box and at a temperature between 

-40˚F and 158˚F and a relative humidity of max. 95% (at 77°F). Check that the packaging has not been damaged during 

transport.

1 x Air Conditioner
1 x Instruction Manual with technical information
1 x Mounting Template in 1:1 scale
1 x Installation pack containing:

11 x M6 Bolts
11 x A6.4 Toothed Washers
11 x A6.4 Washers
1 x Female Connector with shorted wired positions for door contact

Saginaw Control and Engineering

95 Midland Road
Saginaw, MI 48638-5770
Phone: (989) 799-6871
Fax: (989) 799-4524 

[email protected]

 Always switch power supply off before starting any maintenance on the unit.

Any repairs that may be needed must only be done by qualified personnel. The cooling unit is a low maintenance type and 

for most environments, no filter is required. If an air filter is installed, check it periodically for dirt and clogs. Clean or replace 

filter when necessary.

Disposal

The cooling unit contains R134a refrigerant and small quantities of lubricating oil. Replacement, repairs and final disposal 

must be done according to the regulations of each country for these substances.

Summary of Contents for Enviro-Therm SCE-AC10200B460V3

Page 1: ...ng p 7 8 Mounting Principle p 7 9 Cutout Dimensions p 8 10 Dimensions H x W x D p 8 11 Electrical Connection p 9 12 Controller Programming p 9 13 Wiring Diagram p 13 14 Taking Into Operation p 15 15 R...

Page 2: ...ltage Indicates electric shock danger Important Safety Instruction Indicates instructions for safe maintenance and operation of the unit Attention Indicates possible burns from hot components Attentio...

Page 3: ...y regulations One can find dangerous voltage above 50V AC or above 100V DC Behind the control cabinet doors On the power supply in the unit housing The units have to be fused according to the type pla...

Page 4: ...ke and evaporator These four components of the refrigerant plant are connected with each other by pipes to form a hermetically sealed system in which the refrigerant R134a circulates 1 Air Intake Cabi...

Page 5: ...Steel Powder Coated SS Stainless Steel AISI 304 SS6 Stainless Steel AISI 316 Dimensions H x W x D 61 02 x 18 00 x 13 98 inch Weight 176 lbs Cutout Dimensions 14 80 x 12 80 inch 14 80 x 13 20 inch Rate...

Page 6: ...e C Cooling Capacity BTU SCE AC10200B230V SCE AC10200B460V3 SCE AC10200B230VSS SCE AC10200B460V3SS SCE AC10200B230VSS6 SCE AC10200B460V3SS6 Enclosure Air Temp 131 F 55 C 122 F 50 C 95 F 35 C 68 F 20 C...

Page 7: ...tering the cooling unit internal and external are not obstructed Cooling unit enclosure air suction hole must be installed at the highest possible point When installing the unit on a door ensure it ca...

Page 8: ...op 9 Cutout Dimensions 17 99 14 02 61 02 61 02 17 99 1 97 12 80 12 01 13 19 21 06 14 84 8 07 8 07 93 98 98 1 58 16 14 13 19 11 22 14 57 14 17 6 89 312 x11 MOUNTING PATTERN INTERNAL AIR OUTLET INTERNAL...

Page 9: ...t must be closed when the cabinet door is closed The cooling unit is intended to be used as a complementary accessory to larger industrial equipment The unit is used where heat needs to be dissipated...

Page 10: ...ss Flashes when activation is delayed or inhibited by protection times external disabling or other procedures in progress Flashes when alarms are active Signals operation of unit in heating mode Activ...

Page 11: ...high temperature alarm threshold default 55 C 131 F 3 Press SET on the desired parameter to display the current value 4 Use or to reach the desired value 5 Pressing SET temporarily saves the new value...

Page 12: ...no button is pressed for 10 seconds the display starts flashing and after 1 minute returns to the main display without saving changes l To increase scrolling speed press and hold the or button for at...

Page 13: ...Motor Overload Protector AR Alarm Relay X4 Electrical Supply Connections 1 L1 380 415 400 460 V 50 60 Hz 3 2 L2 380 415 400 460 V 50 60 Hz 3 3 L3 380 415 400 460 V 50 60 Hz 3 4 Earth Ground 5 P1 High...

Page 14: ...B 14 SAGINAW CONTROL ENGINEERING A C USER MANUAL back to top...

Page 15: ...ing temperature St Verify values of parameter St Door switch contact is open Verify door switch Controller does not work Replace controller Internal fan works external fan and compressor do not work D...

Page 16: ...shers 1 x Female Connector with shorted wired positions for door contact Saginaw Control and Engineering 95 Midland Road Saginaw MI 48638 5770 Phone 989 799 6871 Fax 989 799 4524 sce saginawcontrol co...

Page 17: ...ot exceed minimum and maximum rated temperatures Must not exceed BTU Hr rating Filters must be cleaned regularly Must be installed and grounded in accordance with all relevant electrical and safety co...

Reviews: