4.2 Programming Direct Access Keys (DAK)
The FUT station has got 3 DAKs (F1, F2, F3). In add ition two DAK features can be accessed by
external keys. The relation between DAK key and DAK programming is as following:
DAK line in programming window
DAK key
1
External DAK1
2
External DAK2
3
DAK key F1
4
DAK key F2
5
DAK key F3
Programming example
Function key F1 = DAK3 switches to volume setting 3 (silent)
Function key F2 = DAK4 switches to volume setting 6 (loud)
Function key F3 = DAK5 switches the station to
Private mode
By dialling function code 7886 the station is switched back to
Open mode