Installing i-on Control Units
Page 36
Re-fit the lid, then switch on the mains supply to the control unit.
Go through the initial configuration prompts and set up the system as described in the
Configuration Guide
. You are prompted to specify installer and user codes during initial
system configuration.
It is recommended that you connect the control unit to the internet and enable “Level 4
Update” in the installer and user menus. When you enter your installer code, the system
can then check online whether later versions of the firmware or language file exist, and
prompt you to install them. Please refer to the
Configuration Guide
for further details.
i-onG3MM Installation Instructions
During installation, please refer to Figure 17 and to
Overview of PCB links, connectors and
on page 40.
Figure 17. i-onG3MM: Control unit PCB
k
Kick-start link
Connect transformer
n
Bus 1 RS485
termination
Connect battery lead
Output
device
Bus 2 device
(e.g. keypad)
e
Bus 2 devices
c
Engineer keypad
port
j
Network
port
f
Open-collector outputs
For engineering
use only
g
Loudspeaker
m
Auxiliary tamper
h
Siren/strobe unit.
Note:
If
a wired siren/strobe unit is
not fitted, connect TR to 0V.
a
SD card slot
b
Reset codes link
i
Zones
0 to 9
l
Plug-on module
socket
d
Plug-by communicator ports
o
HB LED
o
3V3 LED
o
LNK/
ACT LED
f
Relay outputs
1 and 2
0V/12Vdc outputs
Connect tamper switch
i-onG3MM
e
Bus 1 devices
Bus 1 device
(e.g. keypad)
n
Bus 2 RS485